5. Connect a regulator valve, an in-line shut off valve and a 1/4" NPT air hose to the Quick Coupler (76) (all sold
separately). The air hose must be long enough to reach the work area with enough extra length to allow free
movement while working.
An in-line shutoff ball valve is an important safety device because it controls the air supply even if the air hose is
ruptured. The shutoff valve should be a ball valve because it can be closed quickly.
6. Depending on the tool which you will be using with this compressor, you may need to incorporate additional
components, such as an in-line oiler, a filter, or a dryer (all sold separately). Consult your air tool's manual for
needed accessories.
GENERAL OPERATING INSTRUCTIONS
Read the ENTIRE IMPORTANT SAFETYINFORMATION section at the beginning of this manual including all text
under subheadings therein before set up or use of this product.
1. Close the Drain Valve (66).
2. Make sure all nuts and bolts are tight.
3. Close the in-line Shutoff Valve between the compressor and the air hose.
4. Make sure the air tool's throttle or switch is in the off position.
5. Connect the air tool to the air hose.
6. Plug the Air Compressor Power Cord into a grounded 120 V electrical outlet.
7. Open the in-line Shutoff Valve.
8. Turn the Power Lever ON.
9. Allow the Air Compressor to build up pressure until it cycles off.
At the beginning of the day's first use of the Air Compressor, check for air leaks by applying soapy water to connec-
tions while the Air Compressor is pumping and after pressure cut-out. Look for air bubbles. If air bubbles are
present at connections, tighten connections. Do not use the air compressor unless all connections are air tight, the
extra air leaking out will cause the compressor to operate too often, increasing wear on the compressor.
As long as the Power Lever is ON, the operation of the Air Compressor
is automatic, controlled by an internal pressure switch. The compressor will turn on automatically when the air
pressure drops to 95 PSI as indicated on the Tank Pressure Gauge (53), and will turn off automatically when the
air pressure reaches 115 PSI as indicated. IMPORTANT: The internal pressure switch is not user adjustable, do
not make changes to the air pressure settings of the internal pressure switch. Any change to the automatic pres-
sure levels may cause excess pressure to accumulate, causing a hazardous situation.