3 . Technical Specifications
Mechanical and installation
Parameter
Dimensions
Weight
Altitude
Input cable cross section
Input cable diameter
Degree of protection
Noise emission
Charging mode
Mechanical strength
Pollution degree
Support for ventilation
Access
General
Parameter
Rated voltage (Un)
Rated current (In)
Rated frequency
Standby power consumption
Ambient operating temperature
Maximum charging power
Protection class
Overvoltage category
Test condition
Including backplate
With fan running
Installation
environment
According to EN
61851-1 6.3.2.2
According to EN
61851-1 5.4
Test condition
Phase-Neutral
Phase-Phase
TN 3 phase @ 32 A
TN 1 phase @ 32 A
IT 3 phase @ 32 A
(Norway only)
IT 1 phase @ 32 A
(Norway only)
Min
Typ
H: 392 W: 258
D: 112
5
2.5
13
IP54
Mode 3, case B
IK10
4
No
Restricted and non-restricted access
Min
Typ
207
230
360
400
32
50
3
-30
22
7.4
12.7
7.4
I
III
English
Max
Unit
mm
kg
2000
m
10
mm²
18.5
mm
47.5
dBa
Max
Unit
253
V
440
A
Hz
W
40
°C
kW
7