EN
What
Whips
Hydraulic connectors
Nuts and bolts
Beam
Moving parts
CAUTION
Residual hydraulic energy
The pressurised hydraulic fluid must release residual energy before carrying out any maintenance or repair work on the log
splitter. Hydraulic fluid can be highly pressurised even when the engine is switched off. Escaping pressurised hydraulic fluid can
penetrate the skin and cause serious injury. To release residual hydraulic pressure:
1. Shut off the engine.
2. Move the control valves back and forth, from one travel limit to the other, at least four times.
3. Hold the valve for three seconds at each travel limit.
WARNING
Skin injection hazard.
High-pressure fluid can inject under the skin and cause serious injury, including amputation.
-Make sure all connections are tight before applying pressure. Relieve system pressure before servicing.
-Do not check for leaks by hand. Instead, use a piece of cardboard to check for leaks.
-If a cut injury occurs, seek professional medical help immediately.
When
Inspect exposed wire mesh and for leaks. Replace all worn or dama-
Every use
Inspect for cracks and leaks. Replace all damaged connections
Every use
Every use
Every use
Cada uso
How
ged hoses before starting the engine.
before starting the engine.
Check for loose screws
Apply grease to the beam surface.
Cleaning up waste
33