Heating of the water
Time interval
Max outlet
(s)
temp( )
10
20
30
6.8.9 Effectiveness of the protection against accidental overheating of thermostatic appliances
Test condition
Max water
temperature
of outlet( )
Test n° 1
Combustion I
2H
Burner position
C32
Rf gas, 1.05Rate
Rf gas, Pn
incomplete gas,
1.05 Rate
Rf gas, low
Rf gas, Pn, 0.85V
Rf gas, Pn, 1.10V
Flame lift gas,
0.95Qmin
C12
Rf gas, 1.05Rate
Rf gas, Pn
incomplete gas,
1.05 Rate
Rf gas, low
Rf gas, Pn, 0.85V
Rf gas, Pn, 1.10V
Flame lift gas,
0.95Qmin
Water temp of
water
steady-
state( )
59.8
59.6
60.1
59.8
60.3
60.1
Water
temperature
of inlet( )
79.6
20.8
CO
%
CO
%
M
2M
105
7.30
84
6.67
244
8.04
103
3.14
95
6.60
87
6.58
264
2.71
280
8.15
182
7.77
850
8.61
78
3.49
248
8.11
185
7.83
242
2.78
24
Water temp
Allowed
rise(K)
temp
rise(K)
0.2
20
0.3
20
0.2
20
Limit
Allowed
control
temp ( )
( )
85
95
CO
%
AFCO %
2N
11.7
0.0168
11.7
0.0147
12.2
0.0370
11.7
0.0384
11.7
0.0168
11.7
0.0155
11.9
0.1159
11.7
0.0402
11.7
0.0274
12.2
0.1204
11.7
0.0261
11.7
0.0358
11.7
0.0276
11.9
0.1036
Result
Pass
Pass
Pass
Result
Pass
Limit %
Pass or
Fail
0.1
Pass
0.1
Pass
0.2
Pass
0.1
Pass
0.2
Pass
0.2
Pass
0.2
Pass
0.1
Pass
0.1
Pass
0.2
Pass
0.1
Pass
0.2
Pass
0.2
Pass
0.2
Pass