Evaporator coil temp. sensor
C
detect range
Return gas temp. sensor
D
detect range
Ambient temp. sensor
E
detect range
Electronic expansion valve
F
step
Temp of solar thermal
H
collector
Malfunctioning of the unit and error codes
When an error occurs or the protection mode is set automatically, the circuit board and the wired
controller will both display the error message.
Protection/
Error
Malfunction
code
Standby
Normal
running
P1
Lower tank
water temp.
sensor failure
P2
Upper tank
water temp.
sensor failure
P3
Evaporator
coil temp.
sensor failure
P4
Return air
temp sensor
failure
Ambient
P5
-9 ~ 99°C
-9 ~ 99°C
-9 ~ 99°C
-9 ~ 99°C
0-140℃
LED
Possible reasons
indicator
Dark
Bright
1) The sensor open
☆●
circuit
(1flash
1 2) The sensor short
dark)
circuit
3) PCB board failure
1) The sensor open
☆☆●
circuit
2) The sensor short
(2 flashes 1
circuit
dark)
3) PCB board failure
1) The sensor open
circuit
☆☆☆●
2) The sensor short
(3 flashes 1
circuit
dark)
3) PCB board failure
1) The sensor open
☆☆☆☆●
circuit
(4 flashes 1
2) The sensor short
circuit
dark)
3) PCB board failure
☆☆☆☆☆
1) The sensor open
Actual testing value. Error code P3
will be shown in case of a malfunction
Actual testing value. Error code
PP4 will be shown in case of a
malfunction
Actual testing value. Error code
PP5 will be shown in case of a
malfunction
N*10 step
Measured value,if failure,show P6
1) Check the sensor
connection
2) Replace the sensor
3) change the PCB board
1) Check the sensor
connection
2) Replace the sensor
3) change the PCB board
1) Check the sensor
connection
2) Replace the sensor
3) change the PCB board
1) Check the sensor
connection
2) Replace the sensor
3) change the PCB board
1) Check the sensor
75
Corrective actions