INCLUDED
Hardwired Room Sensor Part No. 1110725
User Manual
Quick Start Guide
Wire Nuts: Quantity 3
CONTROL SPECIFICATIONS
• cULus Listed
• 120 VAC 60 Hz Line Power
• Typical Wire Sizes: 12 AWG (MAX) or 14 AWG solid
wire rated for at least 90°C
• Operating temperature: 32-95°F (0-35°C)
• Purpose of Control: Flush Mount Operating Control
• Rated impulse voltage: 2500 V
SAFETY
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Before installing the Hardwired Room Sensor,
switch power off at the service panel and lock the
service disconnecting means to prevent power from
being switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to
the service panel. CAUTION: Risk of Electric Shock -
More than one disconnect switch may be required to
de-energize the equipment before servicing.
2. All electrical work must be done in accordance with
local codes, ordinances, or National Electrical Code,
as applicable, including fire-rated construction codes
and standards. FOR SAFETY, THIS PRODUCT MUST
BE GROUNDED. If you are unfamiliar with methods
of installing electrical wiring, secure the services of
a qualified electrician.
3. Use copper conductor only.
4. Install only in a UL Listed dual-gang junction box sized
4.0 x 3.0 x 3.0 in. (101.6 x 76.2 x 76.2 mm) or larger,
with a minimum volume of 30.0 in³ (491.6 cm³) and
a minimum depth of 3.0 in (76.2 cm).
5. This control requires a neutral wire for operation.
6. When cutting or drilling into wall or ceiling, do not
damage electrical wiring or other hidden utilities.
7. To prevent serious injury from electrical shock or
damage to electrical components - DO NOT WIRE
HOT!
8. The automatic operation feature is Type 1 action,
according to UL 60730-1.
9. The enclosure protection rating is IP10.
10 The product is Pollution Degree 2, which is intended
to be used in a household environment or similar.
11. The devices are not intended for use in locations
where the temperature may be less than actual room
conditions, such as unheated warehouses or garages.
12. Avoid water and wet locations. Keep the device away from
water, fire, excessive humidity, or hot environments.
13. Do not use the device where wireless devices are not
allowed.
14. Do not attempt to disassemble, repair, or modify
the device. Don't disassemble the product, or make
repairs yourself. You run the risk of electric shock
and voiding the limited warranty. If you need service,
please contact us.
15. Note: When power is applied, the Hardwired
Room Sensor 1110725 may require approximately
30 seconds to boot up and be ready to function.
16. Please read and follow the above safety information
when operating the device. We cannot guarantee that
no accidents or damage will occur due to the improper
use of the device. Please use this product with care
and operate at your own risk.
Warranty is void if miswired.
Overture
HARDWIRED ROOM SENSOR
TM
INSTALLATION
NOTE: This control requires a 120 VAC source (hot and
neutral) in the switch box to operate the Hardwired
Room Sensor.
1. Turn off the power and lockout the service panel before
wiring the control.
2. Location Notes:
a. The control should be placed on interior walls only
at switch box height from the floor.
b. Keep the control away from HVAC equipment such
as heat registers, cold air returns, heaters, fans,
and drafts.
c. Place your Hardwired Room Sensor within the range
of your Wi-Fi router or access point (approximately
100 feet).
d. Avoid physical obstructions and radio interference
in the surrounding area.
3. Install the control in at least a 3" deep dual-gang
junction box. The control can be installed in either a
metal outlet box or a plastic outlet box.
4. Attach the incoming power line to switch box. It may
be necessary to use two side knockouts for some
applications. Use proper connectors. Provide 6" leads
inside box.
5. Make electrical connections following the diagram
below or on the Broan-NuTone Overture
wire nuts. Make sure the control is properly grounded.
6. Tuck wires in and fasten control to junction box using
attached screws. Verify Hardwired Room Sensor
orientation before installation. Note "UP" direction
shown on the front of control.
7. Attach front cover by aligning top locators and snaps
on the bottom. Push to secure.
8. Download the Broan-NuTone Overture
by step set-up instructions to connect your Hardwired
Room Sensor to the Overture
TM
to go to App Store.
For Warranty Statement, Service Parts, Technical
Support, or to Register your product, please visit our
website or call: In the United States - Broan-NuTone.com
800-558-1711. In Canada - Broan-NuTone.ca
800-567-3855
BIAQHWRS100 Wiring Diagram
Power Supplied to Switch Box
120 VAC
LINE IN
Regulatory Information
The Overture
to comply with applicable FCC and IC rules and regulations
governing RF and EMI emissions. Refer to 1110725.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) This
device must accept any interference received, including
interference that may cause undesired operation. The
distance between user and device should be no less
than 20 cm.
FCC Notice
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in
a residential installation. This equipment generates,
uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions
may cause harmful interference to radio communications.
However, there is no guarantee that interference will
not occur in a particular installation. If this equipment
does cause harmful interference to radio or television
reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to
website. Use
TM
correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV
App for step
TM
technician to help.
Changes or modifications not expressly approved by the
system. Scan QR code
party responsible for compliance could void the user's
authority to operate the equipment.
ISED Compliance Statement
This device contains licence-exempt transmitter(s)/
receiver(s) that comply with Innovation, Science and
Economic Development Canada's licence-exempt RSS(s).
Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including
interference that may cause undesired operation of
the device.
The Bluetooth® word mark and logos are registered
trademarks owned by Bluetooth SIG, Inc. and any use
of such marks by Broan-NuTone LLC is under license.
Other trademarks and trade names are those of their
respective owners.
The Android robot is reproduced or modified from work
created and shared by Google and used according to
terms described in the Creative Commons 3.0 Attribution
License.
Regulatory ID for 1110725 Overture
Sensor
FCC ID: 2ADLL-1110725
IC: 2143B-1110725
CAN ICES-003(B) / NMB-003(B)
Made in China to the quality standards and
specifications of
Broan-NuTone LLC, 926 West State Street, Hartford,
Wisconsin, USA 53027 Broan-NuTone.com
800-558-1711
Venmar Ventilation ULC, 550 Lemire Blvd., Drummondville
Québec Canada J2C 7W9 Broan-NuTone.ca
800-567-3855
Switch Box
For more information and user manuals scan QR code
below.
Hardwired Room Sensor 1110725 is certified
TM
Hardwired Room
TM
1110078A

Publicidad

loading

Resumen de contenidos para Broan-NuTone 1110725

  • Página 1 FCC and IC rules and regulations User Manual neutral) in the switch box to operate the Hardwired governing RF and EMI emissions. Refer to 1110725. Quick Start Guide Room Sensor. This device complies with Part 15 of the FCC Rules.
  • Página 2 émissions d’interférences et de Guide de démarrage rapide fonctionner le capteur intelligent. radiofréquences. Se référer à 1110725. Cet appareil est Capuchons de connexion : quantité 3 1. Couper le courant et verrouiller l’accès au panneau conforme aux exigences de la section 15 des règlements...
  • Página 3 8. La característica de funcionamiento automático es de sus usos por parte de Broan-NuTone LLC se ciñen a una producto, visite nuestro sitio web o llámenos: En los acción tipo 1, según la norma UL 60730-1.