Solution: Contact an authorised service centre
2. Error: No response to air being blown in
Possible cause: Unheated sensor
Solution: Wait until the countdown on the display is over.
Possible cause: Circuit failure
Solution: Contact an authorised service centre
3. Error: "Err" message appears and the device switches off
Possible cause: Sensor malfunction
Solution: Contact an authorised service centre
4. Error: Unable to switch on the device
Possible reason: Discharged batteries
Solution: Replace the batteries
08. SPECIFICATION
Sensor type: Semiconductor
Measurement range: 0~2.00‰ BAC (0~1.00mg/ L; 0~2.00g/ L; 0~0.20% BAC;
0~1.00mg/ L).
Measurement resolution: 0.01BAC‰
Operating temperature: 0~50 ℃
Standby time: Approximately 35 s
Permissible air humidity: ≤ 93 %
Display: LCD
Batteries: 2x 1.5V AA
Dimensions: 124x44x19 mm
Weight: 49g (without battery)
Error range: ± 0 . 1‰ BAC for 0.5BAC‰
09. WARRANTY CARD
The product comes with a 60-month warranty. Warranty conditions can be found
at: https://xblitz.pl/gwarancja
Complaints should be made using the complaint form found at: https://reklamacje.
kgktrend.pl/
Details, contact and address of the service can be found at: www.xblitz.pl
Serial number......................................................
The guarantee is only valid if the device is regularly serviced and calibrated at an au-
thorised service centre at least once a year. The device has been correctly calibrated
since new. Every breathalyser offered on the market requires periodic calibration,
i.e. every 12 months (every 6 months is recommended), the device must be confi
gured so that it correctly interprets the amount of alcohol in the air exhaled. The
need for recalibration is not a defect in the device and is not subject to warranty. A
device that is not regularly calibrated will show erroneous results.