Descargar Imprimir esta página

Pfister Avalon LF 36 Serie Instrucciones De Instalación página 4

Grifo para la cocina

Publicidad

Idiomas disponibles

Idiomas disponibles

8
8C
8 SECURING FAUCET
Align Faucet (8A) to sink surface. From underneath sink, secure faucet and Hose Guide
(8B) by using Wingnuts (8C). Hand tighten.
9
9B
9A
HOT
9A
9 WATER SUPPLY CONNECTIONS
Connect water Supply Lines (9A) to Faucet Inlets (9B). Hot water supply lines go into
left inlet. Cold water supply lines go into right inlet. (Supply lines not included). Please
follow manufacturer's instructions when installing suppy lines.
10
10 UNIT START UP
Turn on water supply inlet valves and check for leaks.
8A
8B
8C
9B
COLD
ENGLISH
FAUCET FUNCTIONS
11
HOT
ON
11 FAUCET FUNCTION
COLD valve: close-counterclockwise, open-clockwise; HOT valve: close-clockwise,
open-counterclockwise. The Spout (11A) can be rotated around the Faucet Body in
any direction.
12
12 SIDE SPRAY OPERATION
The Side Spray (12A) can be pulled forward to spray water in any direction. To activate
the Side Spray, press the Toggle Button (12B) located on the back of the Side Spray (12A).
MAINTENANCE & CARE
13
13E
13D
13C
13 FLUSHING & AERATOR CLEANING
After installation is complete, remove Aerator Housing (13A). Turn Valves (13B) on
and allow both hot and cold water to run for at least one minute each. While water is
running, check for leaks. To clean the aerator, disassemble Aerator Housing (13A) by
separating the Aerator Head (13C), Basket (13D) and Washer (13E). Once parts have
been cleaned, reassemble by reversing steps.
4
COLD
ON
11A
12B
12A
13A
13B

Publicidad

loading

Este manual también es adecuado para:

Avalon lf-036-4cb