3.6.
PERSONNEL QUALIFICATIONS
Trained specialist for electro-technical work
A trained electrician in terms of this document is a person who has been respectively trained and who possesses the skills
and experience to recognise and avoid the dangers of working with electricity.
Specialists for mechanical work
Specialists in the sense of this documentation are persons who are familiar with assembly work, mechanical installation,
commissioning, troubleshooting and maintenance of the products and who possess the following qualifications:
Qualification / training in the field of mechanics as specified in the nationally applicable regulations.
Trained person
Trained persons in the sense of this documentation are persons who have been trained to perform work in the areas of
transport, storage and operation.
4.
Device overview
A
1 Mounting bracket 2 Casing 3 Reset knob for overload protection 4 Stop 5 Mains plug 6 Mains connection of the
cable reel
5.
Attachment to a wall or ceiling
B
C
D
,
,
ü Select plugs and screws for the respective wall or ceiling.
1. Place the mounting bracket on a flat surface, mark the positions of two drilled holes.
2. Drill the holes and screw the mounting bracket to the mounting surface using suitable plugs and screws.
6.
Operation
6.1.
PULLING OUT THE CABLE
E
1. Slowly pull the Cable out to the desired length.
▶ Take care to pull the Cable out in a straight line.
2. To lock it, let go the Cable.
6.2.
RETRACTING THE CABLE
F
1. To release the lock, pull slowly on the Cable then let it go.
▶ The Cable will retract back into the casing.
2. Guide the Cable whilst it is retracting.
7.
Maintenance
Interval
Before each occasion of use
Before each use
8.
Faults
Fault
Cable not reeling in fully.
Connected consumer failing
to start or switching itself off.
Maintenance work
Visually check the cable reel and
cable for damage to the insulation,
such as exposed core wires or dam-
age to the cable sheath.
Check power sockets for bent earth
contacts. There must be no scorch
marks at the plug holes.
Repair defects and damage or replace.
Possible cause
Cable jams or catches when
reeling in.
Cable reel not connected
to mains.
Performed by
Trained person
Trained specialist for electro-technical
work
Hoffmann Group Customer Service
Action
Extend Cable to full length,
allow it to reel in freely.
Check fuses.
Plug cable reel into mains.
Performed by
Trained person
Trained person
www.hoffmann-group.com