Maintain reel by following the instructions given below.
Refer all other repairs, other than those listed, to Uline
Customer Service at 1-800-295-5510. Failure to do so
can result in personal injury and/or equipment damage
and may void the warranty.
WARNING! Remove power from reel before
performing any of the following procedures.
REPLACING THE OUTPUT ELECTRICAL CORD
WARNING! Select output cable in accordance
with power requirement of apparatus to be
supplied. Ensure that application does not
exceed electrical rating of reel. Use extreme
caution, reel under tension. Avoid releasing
latch mechanism.
Figure 3
5
4
3
2
1
1.
Pull output electrical cord from reel until fully
extended, then latch.
See Figure 3 for the following steps:
2. Remove output electrical bumper stop (7).
3. Disconnect output electrical cord/work device (12)
at terminal strip (10).
4. Remove strain relief (8). Remove output electrical
cord/work device.
5. Install replacement electrical cord/work device by
reversing steps 2 through 4.
6. Release latch and rewind electrical cord on reel.
7.
Replace access cover (1).
PAGE 3 OF 9
7
8
6
15
13
12
14
SERVICE
REPLACING THE INPUT ELECTRICAL CORD
WARNING! Use only 12/3 or 16/3 cable for input
wiring. Ensure that applicatoin does not exceed
electrical rating of reel. All cord reels with GFCI
receptacles must be hard wired into the electrical
circuit. Use of 2 or 3 prong plugs may cause a
potential malfunction of the GFCI receptacle
1.
Remove wire nuts (15) securing input electrical cord
to collector assembly (13).
2. Remove 90 degree elbow (9).
3. Remove input electrical cord.
4. Remove 11" of outer jacket from replacement input
electrical cord (input electrical cord wires must protrude
a minimum of 6" from center of collector assembly).
5. Install replacement input electrical cord by reversing
steps 1 through 3.
6. Replace access cover (1).
REPLACING THE BRUSH HOLDER/BRUSHES
1. At terminal strip (10), remove wires connecting
brushes (11) to terminal strip.
9
2. Remove lock nuts (3) securing brush holder (6) to
10
reel. Relocate cable clamp temporarily and remove
brush holder.
3. Remove brushes (4) from brush holder (6).
4. Install replacement brush holder/brushes by
reversing steps 1 through 3. Upon completion
11
of installation, adjust brush-to-ring alignment by
loosening nuts (5) and sliding finger assembly (2).
REPLACING THE COLLECTOR ASSEMBLY
1.
Remove wire nuts (15) securing input electrical cord
to collector assembly.
2. At terminal strip (10), disconnect wires (11)
connecting brushes (4) to terminal strip.
3. Remove lock nuts (3) securing brush holder (6) to
reel. Relocate cable clamp temporarily and remove
brush holder.
4. Remove snap ring (14).
5. Remove collector assembly (13).
6. Install replacement collector assembly by reversing
steps 1 through 5. Upon completion of installation,
adjust brush-to-ring alignment by loosening nuts (5)
and sliding finger assembly (2).
7.
Replace access cover (1).