Descargar Imprimir esta página

Last Calor EVA 2016 Manual De Instalación, Uso Y Mantenimiento página 39

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

6.3 Stove internal parts
Key:
1 - Combustion chamber
2 - Support left and right
3 - Cast iron exchanger
4 - Vermiculite side walls
5 - Vermiculite upper baffle
6 - Vermiculite rear wall
6.4 Electrical components
7 TROUBLESHOOTING
7.1 Alarm management
Alarms are indicated by an acoustic signal (if activated) and a message on the control panel.
In case of an alarm the shutdown procedure is automatically activated. Cancel the signalling by pressing button P3
and wait until the stove reaches OFF status. Eliminate the cause and restart the stove according to the normal
procedure described in this manual.
Listed below are the alarms that can appear on the control panel, with the causes and cures:
Signalling
Occurs in case of a power
AL 1
failure during the operation
POWER
phase
FAILURE
ALARMS - MESSAGES
Fault
Electrical system power failure
in the stove installation room
Key:
1 - Electronic board N100
2 - Safety thermostat
3 - Room probe
4 - Safety vacuum switch
5 - Fume probe
6 -Gearmotor
7 - Fume extractor
8 - Rear tangential fan
9 - Control panel
Possible causes
39
Cures
- Turn the stove OFF by
pressing button P3 and repeat
the lighting procedure
- Other reinstatement
operations must be carried
out by a service centre
EVA-2016

Publicidad

loading

Productos relacionados para Last Calor EVA 2016

Este manual también es adecuado para:

La11x00x