ElectricalShock Or Personal Injury
Hazard
Disconnect electricalsupply before
servicingor cleaning the unit. Failure
to do so could resultin electricalshock
or personal injuryfrom cleaner sud-
donly starting.
Frequentlycheck and remove hair, string
and lintbuild-up in the brush area. If build-
up becomes excessive,follow the steps
below.
TO REMOVE BELT
Disconnect power cord from electrical outlet.
Carpet/Bare
Roor Selector
Place the
carpet/bare
floor selec-
tor in the
carpet posi-
tion and
To Carpet
lower han-
Position die to lay
vacuum flat.
Slide latches
outward and
remove noz-
zle cover.
Nozzle
Latches
Agitator
Cover
Furniture
Guard
Retainer
Unfasten the
furniture
guard retain-
ers from the
posts on both
sides of the
agitator
cover.
Depress tabs on
rear of agitator
cover and rotate
forward to
release from the
nozzle body,
The light bulb socket assembly does not
have to be removed, Lay the agitator
cover over to the side out of the way.
Be/t
Position hands on the agitator. If the belt is
still attached to the agitator, there will be
tension on the agitator. Carefully lift the right
end of the agitator and then the left end.
Note: It may be necessary
to pull the edge
of the furniture guard out of the way to allow
the ends of the agitator to be removed easily.
Remove the belt from the motor drive shaft.
Personal InjuryHazard
Be careful when removingthe agitator
as the belt tension Is high. Failure to
do so could result in personal injury
from the agitator releasing quicklyand
snapping away.