Descargar Imprimir esta página

Elkay LZOTL8WS 1A Serie Manual De Instalacion Y Uso página 15

Ocultar thumbs Ver también para LZOTL8WS 1A Serie:

Publicidad

INSTRUCTIONS CONTINUED.....
Refrigerated Cooler side:
Carefully tip the shroud/basin assembly toward the cooler
frame.
Connect black wires from shroud assembly to solenoid
valve and to the piggyback connector on solenoid;
connect red wire to open terminal on solenoid; connect
sensor white wire to white jumper wire connected to power
cord.
Disconnect the water line at the solenoid valve. Reference
(Fig. 27, Pg.19) for the operation of the quick connect
fi ttings.
Non-Refrigerated Cooler side:
Carefully tip the shroud/basin assembly
toward the cooler frame.
Connect sensor black wire to piggyback
connector on solenoid; connect red wire
to open terminal on solenoid; connect
sensor white wire to white jumper wire
connected to power cord.
Re-connect the water line at the
solenoid. Reference (Fig. 27, Pg.19)
Precautions need to be taken when
replacing the Basin/shroud assembly:
1) Make sure all wires are inside
frames so as not to become pinched.
2) Water line coming from bottle fi llter
drain must be pulled down as not to
interfere with the fan operation. The
fan blade needs to spin freely.
.
EZOTL8WS*1A LZOTL8WS*1A
Swap drain parts in shroud:
Loosen each hose clamp retaining
the drain pieces.
Remove each drain piece and swap
to other basin.
Tighten each hose clamp.
Using a #T20 (6 point star bit),
tighten the shroud screws.
Fig. 21
Both sides, both coolers, being
careful not to overtighten.
Page 15
Fig. 18
Fig. 19
INSTALL WRAPPERS &
TRIM STRIPS PER PAGE 11
SEE PAGES 16 & 17 FOR
PLUMBING DIAGRAMS
1000005926 (Rev. E - 08/23)
Fig. 20

Publicidad

loading

Este manual también es adecuado para:

Lzo sereieEzotl8ws 1a serieEzo serie