EN
Installation Manual
USA and Canada
Service Office Dometic
1 Sierra Place
Litchfield, IL 62056-3029
877-663-8396 (option 1)
Specifications
Rating
125 V 30 A
Cord type
S, SO, SOO, ST, STO, STOO, SOW, SOOW, STW, STOW,
STOOW, SE, SEO, SEOO, SEW, SEOW, SEOOW
Maximum
8 AWG/3C
Wire Gauge
Installation
Failure to obey the following warnings could result in death or
serious injury.
•
Be sure the connector and connecting cables are not connected to a power
source during installation.
•
Only use copper wire.
•
Only use in dry locations.
•
Consult a qualified electrician if the installation instructions are not completely
understood.
q
w
e
r
t
1
Preparing the wires
q
Copper
w
Black Wire
Green Wire
e
1.
Remove the original cord end.
2. Strip the outer jacket back from the end of the cord by 1.57 in. (40 mm). Be
careful not to cut into the insulation of the inner wire.
3. Strip 0.47 in. (12 mm) off the end of each wire.
AC12490
Service center and dealer locations
Visit: www.sierraparts.com
0.47''
(12mm)
1.57''
(40mm)
r
White Wire
t
Jacket
Form No. 4445103979 2023-03-01 | ©2023 Sierra International LLC
30 A 125 V L5-30R female connector
w
q
2
Disassembling the connector
Clamp screw
q
w
Clamp
e
Grip section
4. Loosen the clamp screws.
5. Remove the clamp from the shell.
6. Loosen the body screws.
7. Remove the body from the shell.
8. Insert the cord through the grip section.
q
w
3
Wiring the terminals
W terminal
q
w
G terminal
9. Connect the exposed copper on each of the wires to the appropriate terminal
and tighten the terminal screws securely.
–
White or gray wire (neutral) to the W terminal
–
Green wire to the G terminal
–
Black wire to the X, Y, or unmarked terminal
10. Reassemble the body and clamps to the shell.
11. Tighten all screws.
Cancer and Reproductive Harm
www.P65Warnings.ca.gov
e
r
t
Body
r
t
Body screw
X, Y, or unmarked terminal
e
WARNING
e