Clarifications on the keyboard lock mode
When activating the keyboard lock, the set mode and the temperature set point are recorded.
If the keyboard lock is enabled:
• The device will return to the modes and temperature set-point before using the keyboard lock
feature if there is a power outage after the next recovery.
• Any change with the selector switch or the set-point temperature, and BOOST or DRYER
buttons has no effect.
• The BOOST, DRYER, MORNING, EVENING and MORNING+EVENING modes will continue
to function normally.
• The OFF mode is a priority, so if the switch is turned to OFF the device will be turned off.
• If returned to ON mode, when the keypad is blocked the device goes back to working in the
mode set before the keypad was blocked.
Keyboard lock indicator:
The DRYER LED flashes quickly once to indicate the keyboard lock is enabled.
• DRYER not enabled => OFF LED, switched off, with flashing once a second.
• DRYER enabled => ON LED, switched on, with switching off once a second.

RESET Function

Press BOOST and DRYER buttons
simultaneously for 30s to reset
device.
This function is similar to a long
power failure. Having reset the
product, the MORNING and
EVENING programs will be
cancelled.
Temperature error
Flashing LED red / green alternately
=> temperature error
The problem may be due to incorrect reading of the
inside temperature sensor.
The user cannot intervene to solve the
problem.