Descargar Imprimir esta página

Furrion FSCC40PW2 Manual De Instrucciones página 13

Controlador de carga solar con mppt (detector de punto de conversión óptima) de 40/60 amp para montaje en pared con aplicación bluetooth

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
For a single Furrion 165W solar panel (PN: FSFP16MW2-BL) the voltage at max. power is 17.9V, current
at max. power is 9.7A and the max. power is 165W.
After connecting two panels in series configuration,
The resultant array's voltage at max. power will be 35.8V, current at max. power is 9.7A and total max.
power of the array is 330W.
The Furrion MPPT technology based solar charge controller can function efficiently and convert
almost 98% of its input solar power into charging power with the help of the added voltage resulting
from a series connection of solar panels. The wire gauge of the array can remain the same, as series
configuration will keep the output current same as a single panel. Hence, it is recommended to
connect solar panels in series configuration in an array when using the MPPT solar charge controller.
When connecting solar panels in an array, care must be taken so that the resultant array voltage and
power parameters do not exceed the charger specifications shown below.
Parameter
Maximum input PV power
Maximum PV Open Circut
(
Voltage
V
OC
Wire Size and Fuse Recommendations
● Wiring and installation methods must comply with national and local electrical code/
specifications.
● The wiring specifications of the PV and battery system must be selected according to the rated
currents specified.
● Since the PV outputs can vary due to the array connection method, the minimum wire size must
be in accordance with the maximum array short-circuit current.
● Please use PV Photovoltaic wire for connection of the array to the charge controller.
● It is recommended to install a fuse between the charger and the battery on the positive wire.
Location of the fuse should be closer to the battery. The fuse rate must be 1.2 - 1.5 times more
than the maximum rated charge current of the solar charge controller.
Please check the following table for wiring specifications:
Model
Rated charge
40A charger
(FSCC40PW2)
60A charger
(FSCC40PW2)
40A charger (FSCC40PW2)
)
PV Wire Gauge
current
(AWG)
40A
10
60A
8
Model
520W
95V
Battery Wire
Rated Discharge
Gauge (AWG)
(Load terminals)
8
6
- 12 -
60A charger (FSCC60PW2)
750W
95V
Load terminal
current
wire Gauge
(AWG)
30A
10
30A
10
CCD-0007727 Rev: 06-01-23

Publicidad

loading

Este manual también es adecuado para:

Fscc60pw2