Be sure power is not connected to the garage door opener BEFORE
installing the safety reversing sensor.
To prevent SERIOUS INJURY or DEATH from a closing garage door:
Correctly connect and align the safety reversing sensor. This required
safety device MUST NOT be disabled.
Install the safety reversing sensor so beam is NO HIGHER than 6"
(15 cm) above garage floor.
THE PROTECTOR SYSTEM
When properly connected and aligned, the safety reversing sensor will detect
an obstacle in the path of its electronic beam.
The sending eye (with a amber indicator light) transmits an invisible light
beam to the receiving eye (with a green indicator light). If an obstruction
breaks the light beam while the door is closing, the door will stop and
reverse to full open position, and the opener light will flash 10 times.
The units must be installed inside the garage so that the sending and
receiving eyes face each other across the bottom of the garage door,
between 4 – 6" above the floor. Either can be installed on the left or right
of the door as long as the sun never shines directly into the receiving eye
lens. The invisible light beam path must be unobstructed. No part of the
garage door (or door tracks, springs, hinges, rollers or other hardware) may
interrupt the beam while the door is closing.
The mounting brackets are designed to clip onto the track of sectional
garage doors without additional hardware. When mounting the units on the
wall, the brackets must be securely fastened to a solid surface such as the
wall framing.
Extension brackets provide additional clearance for wall mounting or
additional height needed for floor mounting. If installing in masonry
construction, add a piece of wood at each location to avoid drilling extra
holes in masonry if repositioning is necessary.
Figure 1: Facing the Door From Inside the Garage
Sensor Beam
4-6" maximum
above floor
WARNING
Sensor Beam
4-6" maximum
above floor
Invisible Light Beam
Protection Area
SAFETY REVERSING SENSOR EXTENSION
INSTALLING THE BRACKETS
Be sure power to the opener is disconnected.
Install and align the brackets so the sensors will face each other across the
garage door, with the beam from 4 – 6" above the floor.
They may be installed in one of three ways, depending on your
requirements, as follows.
(Preferred) Clipped onto the left and right garage door tracks.
Fastened to the wall on each side of the garage.
Fastened to the floor. Concrete anchors and wood blocks or extension
brackets will be needed.
GARAGE DOOR TRACK INSTALLATION
Slip the curved arms over the rounded edge of the door track. Snap into
place against the side of the track. It should lie flush, with the lip hugging the
back edge of the track (Figure 2).
If your door track will not support the bracket securely, wall installation is
recommended.
Figure 2: Door track Mount (Right Side)
Door track
Garage door
WALL INSTALLATION WITH EXTENSION BRACKET
1. Place the bracket against the wall and make sure there is enough
clearance for the sensor beam to be unobstructed (Figure 3).
2. If additional depth is needed, an extension bracket or wood blocks can be
used.
3. First, remove middle clip applying
force at the top of the component
and in the direction of the 2 base
holes as shown in the picture below.
4. Use bracket mounting holes as a template to locate and drill (2) 3/16"
diameter pilot holes on the wall at each side of the door, from 4–6" above
the floor.
5. Attach brackets to wall with lag screws (provided with extension
brackets).
6. If using extension brackets or wood blocks, adjust right and left
assemblies to the same distance out from the mounting surface. Make
sure all door hardware obstructions are cleared.
Figure 3: Extension Bracket Mount (Right Side)
Inside Garage
Wall
(Provided with
extension bracket)
1
BRACKET KIT
041A5281-1
Attach with concrete
(Provided with
anchors (not provided)
extension bracket)
Extension
Bracket
Sensor
Bracket

Publicidad

loading

Resumen de contenidos para Chamberlain 041A5281-1

  • Página 1 SAFETY REVERSING SENSOR EXTENSION BRACKET KIT 041A5281-1 INSTALLING THE BRACKETS WARNING Be sure power to the opener is disconnected. Be sure power is not connected to the garage door opener BEFORE Install and align the brackets so the sensors will face each other across the installing the safety reversing sensor.
  • Página 2 FLOOR INSTALLATION WITH EXTENSION BRACKET ALIGNING THE SAFETY SENSORS 1. Use wood blocks or extension brackets to elevate sensor brackets so the 1. Plug in the opener. The indicator lights in both the sending and receiving lenses will be 4-6" above the floor. eyes will glow steadily if wiring connections and alignment are correct.
  • Página 3 SUPPORT ET CAPTEUR D’INVERSION DE SÉCURITÉ 041A5281-1 face de part et d’autre de la porte du garage, le faisceau se trouvant à une AVERTISSEMENT hauteur de 4 à 6 po au-dessus du sol. Ils peuvent être installés de trois manières différentes, en fonction de vos Vérifiez que l’alimentation n’est pas connectée à...
  • Página 4 INSTALLATION AU SOL AVEC SUPPORT D’EXTENSION ALIGNEMENT DES CAPTEURS DE SÉCURITÉ 1. Utilisez des blocs de bois ou des supports d’extension pour élever les 1. Branchez l’ouvre-porte. Les voyants de l’œil émetteur et de l’œil récepteur supports de capteur de sorte que les lentilles soient à 4-6 po au-dessus restent allumés en permanence si les connexions et l’alignement des du sol.
  • Página 5 KIT DE SOPORTES DE EXTENSIÓN PARA EL SENSOR DE INVERSIÓN DE SEGURIDAD 041A5281-1 a través de la puerta de garaje, con el haz a una altura de 4 a 6" por encima ADVERTENCIA del suelo. Pueden instalarse en una de las maneras que se describen a continuación, Asegúrese de que la corriente no esté...
  • Página 6 ALINEACIÓN DE LOS SENSORES DE INSTALACIÓN EN EL SUELO CON EL SOPORTE DE EXTENSIÓN SEGURIDAD 1. Utilice bloques de madera o soportes de extensión para elevar los 1. Enchufe el abrepuertas. Las luces indicadoras de los sensores emisor y soportes del sensor, de modo que las lentes queden a una altura de 4 a 6" receptor se iluminarán de forma continua si las conexiones del cableado por encima del suelo.
  • Página 8 © 2023, LiftMaster LiftMaster All Rights Reserved 300 Windsor Drive Tous droits réservés Oak Brook, IL 60523 114A2401-20 Todos los derechos reservados LiftMaster.com...