WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
• Use this unit only in the manner intended by the manufacturer. If you have
questions, contact the manufacturer at the address or telephone number
listed in the warranty.
• Before servicing or cleaning unit, switch power off at service panel and lock
the service disconnecting means to prevent power from being switched
on accidentally. When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to the service panel.
• Installation work and electrical wiring must be done by qualified personnel
in accordance with all applicable codes and standards, including fire-rated
construction codes and standards.
• Sufficient air is needed for proper combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow
the heating equipment manufacturer's guideline and safety standards such as
those published by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
• When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
• Ducted fans must always be vented to the outdoors.
• Do not use this unit with any separate solid-state speed control device.
• To reduce the risk of fire, use only metal ductwork.
• This unit must be grounded.
• When installing, servicing or cleaning the unit, it is recommended to wear
safety glasses and gloves.
• When applicable local regulations comprise more restrictive installation and/or
certification requirements, the aforementioned requirements prevail on those of
this document and the installer agrees to conform to these at his own expense.
For complete warranty statement and service parts, or to learn more about the instructions
below, please type your model number in on our website.
PM6 Blower Plate Installation
G
S
round
tud
1. Attach blower to mounting plate with (6) 10-24 Hex Nuts (included).
2. Attach ground wire from blower to ground stud with (1) 10-24 Hex Nut (included).
HD1427
NOTES: There are four (4) possible outlet positions for PM6 and PM12: top, front, back and side (1).
Remove selected knock-out from the housing prior to install blower in the hood. The blower can be installed before or after hood installation in the ceiling. However, it is easier to install the hood in the ceiling without internal
blower installed.
The damper can be installed on the housing prior to install the hood in the ceiling with Side and Top outlet positions only. Otherwise, install the damper once the hood is mounted in the ceiling. Position the damper on the
exterior of the hood using 8-18 screws (included).
10" damper (included with the hood) when using PM12, 8" damper (included with PM6 blower kit) when using PM6.
Top Discharge Blower Installation (PM6 shown in FIG. 3 & 5).
Follow same method for PM12.
HD1430
1. Attach blower plate to hood with (4) 10-24 screws (included) as illustrated above.
PM6 Blower Connection
Connectors plate
33
1. Swivel the connectors plate to unhide a connector.
2. Plug the blower power cord in the connector as illustrated above.
INSTALLATION MANUAL
INTERNAL BLOWERS PM6 AND PM12
READ AND SAVE THESE INSTRUCTIONS
For use with compatible Best range hoods. See hood manual for suitability.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high settings. Boilovers cause
B. Always turn hood ON when cooking at high heat or when flambeing
C. Clean ventilating fans frequently. Grease should not be allowed
D. Use proper pan size. Always use cookware appropriate for the size
TO REDUCE THE RISK OF INJURY TO PERSONS
IN THE EVENT OF A RANGE TOP GREASE FIRE,
OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent
4. Use an extinguisher ONLY if:
* Based on "Kitchen Fire Safety Tips" published by NFPA.
FIG. 1
FIG. 3
FIG. 5
!
WARNING
smoking and greasy spillovers that may ignite. Heat oils slowly on low
or medium settings.
food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
to accumulate on fan or filter.
of the surface element.
tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.
steam explosion will result.
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
In the United States
BestRangeHoods.com
800 558-1711
PM12 Blower Plate Installation
G
1. Attach blowers to mounting plate with (12) 10-24 Hex Nuts (included).
HD1429
2. Attach ground wires from blowers to ground studs with (2) 10-24 Hex Nut (included).
Front/Back Discharge Blower Installation (PM12 Front shown in FIG. 4 & 6).
Follow same method for Side Discharge and when using PM6 blower.
HD1431
1. Attach blower plate to hood by inserting the hooks in the slots and using (2) 10-24 screws (included) as illustrated
above.
PM12 Blowers Connection
HD1432
1. Remove the connectors plate.
2. Plug each blower power cord in a connector as illustrated above.
Service parts:
(1) 600
: S97021509
blower
cfm
/
8"
: SV08543
adapter
damper
round
!
• For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and
vapors.
• To avoid motor bearing damage and noisy and/
or unbalanced impellers, keep drywall spray,
construction dust, etc. off power unit.
• This blower has a thermal overload which will
automatically shut off the motor if it becomes
overheated. The motor will restart when it cools
down. If the motor continues to shut off and
restart, have the hood serviced.
• Please read specification label on product for
further information and requirements.
• To reduce the risk of fire and to properly exhaust
air on a ducted installation, be sure to duct air
outside - Do not exhaust air into spaces within
walls or ceiling or into attics, crawl spaces, or
garage.
S
round
tud
G
round
EN
!
CAUTION
In Canada
BestRangeHoods.ca
800 567-3855
S
tud
FIG. 2
Side Discharge
FIG. 4
FIG. 6
1106530A

Publicidad

loading

Resumen de contenidos para Best PM6

  • Página 1 The damper can be installed on the housing prior to install the hood in the ceiling with Side and Top outlet positions only. Otherwise, install the damper once the hood is mounted in the ceiling. Position the damper on the exterior of the hood using 8-18 screws (included). 10" damper (included with the hood) when using PM12, 8" damper (included with PM6 blower kit) when using PM6. Top Discharge Blower Installation (PM6 shown in FIG. 3 & 5).
  • Página 2 Fixer le volet sur la partie externe de la hotte à l’aide de vis 8-18 (incluses). Volet de 10 po (inclus avec la hotte) pour l’ensemble de ventilateur PM12, volet de 8 po (inclus avec l’ensemble de ventilateur PM6) pour l’ensemble de ventilateur PM6.
  • Página 3 Fijar la compuerta en la parte externa de la campana usando tornillos 8-18 (incluidos). Compuerta de 10 pulg. (incluida con la campana) para el conjunto del ventilador PM12, compuerta de 8 pulg. (incluida con el conjunto del ventilador PM6) para el conjunto del ventilador PM6.

Este manual también es adecuado para:

Pm12