TANK INSTALLATION INSTRUCTIONS
Tank Installation for DOT Certifi ed 1 lb. Propane Cylinder(s) (Fig. 1)
• Open easy access tank compartment door(s).
• Locate regulator and swivel it upward by hand to provide better access for cylinder
• Attach cylinder(s) to swivel mount by gently turning clockwise until it is hand tight. Do not overtighten. Do not use tools to tighten.
• Check for gas leaks by using a 50% soap-water solution at the joint of the regulator and cylinder.
• The LP-gas cylinder(s) must be constructed and marked in accordance with the specifi cations for Cylinders, Spheres and Tubes for the
Transportation of Dangerous Goods, CSA B339;
• We recommend using the WMAI 20 lb. tank connection kit model# 20-7512F, which includes (1) 12' extension hose and (1) fuel
filter ( sold separately).
• Disconnect the disposable fuel cylinder when the unit is not being used.
• 1 lb. cylinders must be Dept. of Transportation (DOT) constructed and approved and have an outlet connection compatible with a CGA 600 fi tting.
Tank Installation for 20 lb. Propane Cylinder (Fig. 1a)
• Open easy access tank compartment door.
• Locate regulator and swivel it upward by hand to provide better access for hose end adapter.
• Attach Fuel Filter, Model 20-7512F, to swivel mount by gently turning clockwise until it is hand tight. Do not over tighten. Do not
use tools to tighten.
• Attach WMAI hose end adapter (No. 20-7512F) to fuel filter by gently turning clockwise until it is hand tight. Do not
overtighten. Do not use tools to tighten.
• Check for gas leaks by using a 50% soap-water solution at the joint of the regulator and hose end adapter.
Fig. 1 - 1 lb. Cylinder Tank Installation
ADDITIONAL INFORMATION REGARDING OPTIONAL ACCESSORIES TO CONNECT A
20 LB LP TANK
• Please note: this heater may be operated with (1) remote refi llable propane cylinder max. 20 Lbs.
• Any CSA certifi ed hose with a CGA 600 fi tting and excess fl ow device, that is appropriate for this application, may be used to
connect a 20 lb. propane tank.
• Non-certifi ed or handmade hoses and adapters may not be used to connect a 20 lb. propane tank.
• The use of a fuel fi lter is also recommended but not mandatory. The fuel fi lter can reduce potential contaminants from the 20 lb. LP
tank/hose and extend the life of the heater.
• We recommend using the WMAI 20 lb. tank connection kit model# 20-7512F, which includes (1) 12' extension hose and (1)
fuel filter (sold separately).
EMERGENCY INDOOR USE
Adequate combustion and ventilation air must be provided when the appliance is in use. Refer to General Safety Instructions on
Page 4 for additional information. Only disposable 1 lb. cylinders, marked as PROPANE can be used with this heater. NEVER bring
a refi llable propane cylinder indoors. A fi re or explosion can occur causing property damage, serious injury, or death.
Regulator
Fig. 1a - Remote Tank Installation
FOR US ONLY EXCEPT MASSACHUSETTS
Fuel Filter & Hose
Kit # 20-7512F
Access
Door
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
5
Carefully close the
Door while
positioning the
remote hose
through the
access slot.