12
Replacing the Fuse Assembly
Only 12V pool lights contain a replaceable fuse assembly. Spa lights and 120V
pool lights do not contain a fuse assembly.
Refer to Pool Light Replacement Parts, page 18 for a list of replacement parts.
REPLACING THE FUSE
ASSEMBLY:
1.
Carefully disconnect both
Fuse-Board Flag Connectors
from the light LED board.
2.
Press down the release lever
on the Fuse-Harness Connector
and gently separate the fuse
assembly from the fuse harness.
3.
Plug the new Fuse-Harness
Connector into the light's fuse
harness until they lock together.
4.
Carefully connect both Fuse-
Board flag Connectors onto the
LED board terminals.
Note: DO NOT press down too hard on the flag connectors. This may damage
the board and/or board terminals.
5.
Reassemble the light according to the instructions given in Reassembling the Pool
Light, page 14.