All operating elements and connections can be
found on the fold-out page 3.
1 Operating Elements
1.1 Receiver UR-816D / 1, front side
1 Receiving antennas
2 POWER switch
3 Power LED
4 Selector switch for the receiving channel
5 LED RF shows the reception of a radio signal
(red or green)
6 LED AF shows the reception of an audio signal
7 Volume control VOL
1.2 Receiver UR-816D / 1, rear side
8 Selector switch OUTPUT LEVEL 0 dB/-20 dB to
adjust the level for the XLR output (9)
9 Balanced XLR output
10 Unbalanced output as a 6.3 mm jack
11 Pull-relief for the connection cable from the
power supply unit: Lead the cable around the
hook so that the plug cannot be pulled out of the
jack (12) by accident.
12 Power supply jack DCV INPUT 12 – 18 V for
connection of the supplied power supply unit
1.3 Transmitter UT-16GT/ 1
13 6.3 mm adapter; for connection of an electric
guitar connect this adapter to the 3.5 mm plug
(14) of the transmitter
14 3.5 mm plug; a DC voltage is present at the ring
contact to supply the microphone with power
15 Locking ring to tightly fasten the push-on micro-
phone (22) or 6.3 mm adapter (13)
16 Base to fix the clamping support (23)
17 Selector switch for the transmitting channel
18 Transmitting antenna
19 Control GAIN to adjust the input sensitivity of
the transmitter
20 Cover for the battery compartment
(3 pieces supplied)
10
21 Microphone cartridge
22 Push-on microphone
23 Clamping bracket to fix the transmitter e. g. at
the bell of a wind instrument
24 Momentary pushbutton ON/OFF MUTE; press it
shortly to switch on and to mute the transmitter,
for switching off keep it pressed until the status
LED (25) will be extinguished
25 Status LED
lights up:
transmitter in operation
flashes:
transmitter muted
green colour: battery o. k.
red colour:
low battery
2 Safety Notes
The units (transmitter, receiver and power supply
unit) correspond to all relevant directives of the EU
and are therefore marked with
WARNING The power supply unit is supplied
with hazardous mains voltage. Leave
servicing to skilled personnel only.
Inexpert handling or modification of
the unit may cause an electric shock
hazard.
It is essential to observe the following items:
G
The units are suitable for indoor use only. Protect
them against dripping water and splash water,
high air humidity, and heat (admissible ambient
temperature range 0 – 40 °C).
G
Do not set the receiver into operation, and imme-
diately disconnect the power supply unit from the
mains socket if
1. there is visible damage to the units or to the
mains cable,
2. a defect might have occurred after a drop or
similar accident,
3. malfunctions occur.
The units must in any case be repaired by skilled
personnel.
G
A damaged mains cable of the power supply unit
must only be replaced by the skilled personnel.
G
Never pull the mains cable to disconnect the
mains plug from the mains socket, always seize
the plug.
G
For cleaning only use a dry, soft cloth, never use
chemicals or water.
.