Descargar Imprimir esta página

Home Decorators Collection IZC5401LX-01/BK Guía De Uso Y Mantenimiento página 3

Publicidad

Idiomas disponibles

Idiomas disponibles

Cable Selection
12 VOLT TAP
Total Fixture Wattage
0-60 Watts
61-120 Watts
121-180 Watts
181-240 Watts
241-300 Watts
600W Transformer = (2x300) Watts
900W Transformer = (3x300) Watts
15 VOLT TAP
Total Fixture Wattage
0-60 Watts
61-120 Watts
121-180 Watts
181-240 Watts
241-300 Watts
600W Transformer = (2x300) Watts
900W Transformer = (3x300) Watts
* NOT RECOMMENDED FOR HALOGEN LANDSCAPE LIGHTS
This data is provided as a general guideline. Actual performance will depend on the installation layout, the fixtures, and the condition of the cable.
NOTE: Most LED landscape lighting fixtures can operate with full illumination from 9V down to as little as 6V. It is possible to have extended
length runs with LED fixtures that go beyond the specifications shown in the guidelines above.
FCC Warning
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
0-50 feet
16 AWG
16 AWG
14 AWG
14 AWG
12 AWG
Not Recommended
12 AWG
Not Recommended
12 AWG
Not Recommended
0-50 feet
16 AWG*
16 AWG*
14 AWG*
14 AWG*
12 AWG*
12 AWG*
12 AWG*
3
Cable Length
51-100 feet
16 AWG
14 AWG
12 AWG
Not Recommended
12 AWG
Not Recommended
Not Recommended
Not Recommended
Not Recommended
Cable Length
51-100 feet
16 AWG
16 AWG
14 AWG
14 AWG
12 AWG
Not Recommended
12 AWG
Not Recommended
12 AWG
Not Recommended
101-150 feet
14 AWG
12 AWG
101-150 feet
16 AWG
12 AWG
12 AWG
12 AWG

Publicidad

loading

Este manual también es adecuado para:

Izc5401lx-01/al1008 556 4541008 556 340