Troubleshooting
PROBLEM
The PLP-REM doesn't react to
transmitter commands
The pool lights don't work
or don't change colors
correclty
Transmitter battery
Check battery status:
Push and release any button on the remote. The green LED should still
light up 0,5 second after you released. If the LED stops faster, then the
battery needs to be replaced
Replacing transmitter battery:
• Remove the philips head screw and open the transmitter
• Replace the battery, respecting the polarity
Battery type: A23 12V
SOLUTION
Perform a RESET procedure
Check the battery of the handheld
transmitter (see below)
The transmitter is not paired-
correctly
with
Repeat the pairing process
Reduce
the
distance
handheld transmitter and PLP-REM
and/or remove obstacles
Check the General status light on
the logic board. If it's red, then
the secondary voltage is too high
(>14VAC) or there is a short circuit
Perform a RESET procedure
Check if all connections are made
according to the electrical scheme.
Switch the PLP-REM-300 to ON/
OFF mode (DIP switch nr 1) and
check if the lamps work
+
-
the
PLP-REM.
between
17