1. Remove the end of the filter.
2. Pull out the white insert.
3. Clean the insert with bleach and a brush.
4. Put the insert back and screw back the end
of the filter taking notice of the rubber
gasket.
Pressure adjustment of the accumulator tank:
1. Shut off the pumps.
2. Open a faucet to relieve the system
pressure.
3. Adjust precharge pressure in tank with a
ordinary tire gauge and tire pump at
valve in end of the tank.
4. Start up the system according to start-up
procedure.
Start-up procedure
After pump installation, using the following
procedure can start the system:
• Fill water tank with potable water.
• Open one tap.
• Turn on the pump.
• Close tap once water begins flowing.
• Open each additional tap until all air has
been purged from the system.
• Pump will shut off after taps ar
flowing.
Original instructions