The timer Ref.1032/81 allows to operate on different kinds of electronic locks:
direct activation by means of capacitive discharge
activation with capacitive discharge and 150 mA stop current
security electronic locks
INSTALLATION
It may be mounted on DIN bar or by wall surface by means of 2 screws and spacers (to be bought
separarately).
DESCRIPTION OF TERMINALS
+24
voltage input 22÷27 Vdc
+12 ~ voltage input 10÷15 Vdc or 10÷15 Vac
-/~
common wire
-/~
common wire
SE2
timer adjust input; its activation is possible by connecting it to the voltage common wire
AP
door release output
NO
normally this contact is open
NC
normally this contact is closed
C
this one is common for NC/NO, it is normally connected to the voltage common wire (-/~)
JUMPERS AND ARRANGEMENTS
AR: possibility of recycle
During the operation with jumper AR in position "NO" , the timer will
activate the relay output in presence of the external adjust "SE2"
and for the programmed time only. The input signal is not a decisive
factor. During the operation with the jumper AR in position "SI" , the
timer will activate the relay output min. for the programmed time; if
the input signal "SE2" should last over the programmed time, the
output will keep active.
AMCR: possibility of connecting the common wire of the relay
By default C and -/~ terminal pins are connected each other; if the
jumper is cut, they are separated.
TIME: potentiometer for programming the delay of the activation
of the output relay; the max. delay may be obtained by turning the
potentiometer clockwise.
DISPLAY
LED LI on: input SE2 is active
LED LO on: the relay output is active
TECHNICAL FEATURES
Voltage on + 24: ..............................................................................................................................22÷27 Vdc
Voltage on +12 ~: ..................................................................................................................... 10÷15 Vdc/ac
Continuous current from AP: ....................................................................................................... 125÷170 mA
Timing range: .............................................................................................................................. 1÷30 s ±20%
Functioning temperature: .............................................................................................................. -10÷+45 °C
Max. resistive commutable charge: ....................................................10 A with 24 Vdc / 10 A with 120 Vac
Max. voltage for switching: ................................................................................................ 240 Vac / 110 Vdc
Max. resistive commutable power: ......................................... 1400 VA with 240 Vac / 300 W with 110 Vdc
Min. charge to apply: ...........................................................................................................10 mA with 5 Vdc
Maximum load at 12 Vdc: ....................................................................................................................200 mA
Dimensions (l x h x w): ................................................... 72 (4 DIN modules, each of 18mm) x 75 x 90 mm