TECHNICAL SPECIFICATIONS
MODEL
Type
Voltage Regulator
Max. AC Output
Rated AC Output
AC Voltage
Frequency
Phase
Power Factor
Degree of Protection
Performance Class
Sound pressure level
(measured at 4 m.)*
Sound power level
Model
Type
Stroke
Displacement (cc)
Max. Output
(HP/kW - RPM)
Fuel
Fuel/Oil mix ratio
Fuel tank Capacity (lt)
Rated Continuous
Operation (hs)
Lubricating oil
Lubricating oil capacity (lt)
Starting System
Ignition system
Spark plug type
Lenght x Width x Height
Net Weight
•
Specifications subject to change without prior notice.
•
Generating set ISO 8528
* Measured according to EN ISO 3744 Standard.
The figures quoted are emission levels and are not necessarily
safe working levels. Whilst there is a correlation between the
emission between the emission and exposure levels this
cannot be used reliably to determine whether or not further
NPEGG850
NPEGG2400
NPEGG3800
MC 2700
Brushless, Self-energising, 2-poles, Single phase
Brushless, Self-energising, 2-poles, Single phase
0.85 kW
2,4 kW
2.4kW
0.80 kW
2.0kW
2,0 kW
72 dB(A)
71 db (A)
72.47db (A)
93 db (A)
92.47 db (A)
96 dB(A)
152 F
UP168
UP 168
Air-cooled 4-stroke overhead valve Petrol Engine
Air-cooled 4-stroke overhead valve Petrol Engine
52x38 mm
68x54mm
68 x 54
80
196
196
2.4/1.8
6.5/4.9 -
6,5 / 3000
- 3600
3600
4.2
15
15
6
13
11
0.4
0.6
0,6
Recoil Starter
Recoil Starter
T.C.I.
T.C.I.
E6TC
F6TC
F6TC
440x320x
590x440x
607 x 455 x 524
360 mm
500 mm
30 kg
43,5
43 kg
31
39
NPEGG5200
MC 3000
Condenser Type
Condenser Type
3.8kW
2,8 kW
5.2kW
3.2kW
4.5kW
2,6 kW
230V
230 V
50 Hz
50 Hz
Single phase
Single phase
cos φ = 1,0
cos φ = 1
IP23
IP 23
G1
G 1
72 dB(A)
75.55 db (A)
74.8 db (A)
95.55 db (A)
97 db (A)
96 dB(A)
UP177
UP188
UP 170
77x58mm
88x64mm
70 x 54
270
389
208
9/6.7 - 3600
7 / 3000
13/9.7 - 3600
Unleaded Gasoline
Unleaded Gasoline
- - -
25
10
10
SAE 10W - 30
SAE 10W - 30
1.1
1.1
Recoil / Electric starter
Recoil / Electric starter
Electronic starting
F7TC
680x510x540
612 x 460 x 542
717 x 545 x 612
mm
67 kg
45
78 kg
precautions are required.
Factors that influence the actual level of exposure of work-force
include the characteristics of the work room, the other sources
of noise etc. i.e. the number of machines and other adjacent
processes, and the length of time for which an operator is exposed
to the noise. Also the permissible exposure level can vary from
country. This information, however, will enable the user of the
machine to make a better evaluation of the hazard and risk.
GB
NPEGG6000
NPEGG7500
MC 4500
Brushless,
Self-energising,
2-poles,
Three-phase
3,8 kW
6.0kW
6 / 7.5 kW
5.0kW
5 / 6.8 kW
3,2 kW
230 / 400V
Three phase
76 dB(A)
75.3 db (A)
97 db (A)
96 dB(A)
UP188
UP 177
88x64mm
77 x 58
389
270
9 / 3000
13/9.7 - 3600
25
9
9
12
1.1
1,1
F7TC
680x540x540
mm
69
80 kg
84 kg