Descargar Imprimir esta página

Aqua Optima Aurora AUR002 Manual De Instrucciones página 5

Publicidad

Idiomas disponibles

Idiomas disponibles

the appliance.
5. Dispense water to remove any unfiltered water in the
appliance and top up.
6. Press and hold the filter warning symbol for 3 seconds to
reset the filter timer.
7. The appliance is now ready to use.
To ensure the best performance, the filter cartridge should
be changed after 26.4 gallons / 100L. The maximum rated
capacity of the filter is 40 gallons/181.8L.
CARE & MAINTENANCE
• Water is a foodstuff. We recommend using the filtered
water within 3 days. If the appliance is not used for more
than 72 hours the water system will need draining. Unplug
appliance and take to the sink. Unscrew both drainage
caps located on the underside of the appliance and
remove the silicon bungs over a sink. Allow all water to
drain out of the system. Re-insert the drainage bungs
and screw on the caps. Repeat the process in section 3.
First Use, to refill the appliance to continue use.
• Should the appliance not be used for an extended period
of time (for example a holiday) we recommend that the
filter is removed and placed in a clean plastic bag and
stored in the fridge. This will help to maintain the filter
when not in use. Before using the filter after storage,
follow the preparation and fitting instructions for use as
normal.
• Do not overfill the water tank, do not fill above the "MAX"
fill to avoid risk of water overflow in the inner water tank.
• Any other servicing should be performed by an
authorized service representative.
4. How to use
1. Fill water tank to the "MAX" mark; water
will flow through the filter at a set rate
and may take some time due to the
action of the filter cartridge.
2. Adjust the height of the drip tray to
accommodate the size of the mug
used. Ensure the drip tray is fully
engaged with the appliance. There are
3 height options (A).
3. Place mug or glass on drip tray (B).
4. Press the On/Off button (C).
5. Press the up or down button to select
the desired temperature and volume
settings (D).
6. Press the dispense button to start
dispensing. One beep at the start (E).
7. The dispense button will fade in and
out whilst dispensing and beep twice
once complete.
8. To engage the child lock, press and
hold the lock button for 3 seconds. The
lock button will change from white to
red (F).
Note:
• To stop the cycle at any time press the dispense button.
Once the cycle has stopped it cannot be continued. A
new cycle must be started.
• Sound - all remaining buttons can be turned off (not
sound in 6. & 7. in How to use guide, section 4.) by pressing
and holding the temperature down arrow and the volume
down arrow for 3 seconds in the locked mode.
• The chilled temperature setting
the appliance is chilling the water and will light up white
when the water is chilled. At first use the chiller takes
around 40 minutes to fully cool down the water (can vary
depending on the incoming water temperature).
• The refill icon will turn orange when the water tank needs
refilling.
• The filter icon will turn orange when the filter needs
replacing, at 26.4 gallons/100L usage, follow the filter
preparation and replacement instructions in this manual.
• Extension cords are available and may be used if care is
exercised in their use.
If an extension cord is used
(1) the marked electrical rating of the extension cord
should be at least as great as the electrical rating of the
appliance.
(2) the longer cord should be arranged so that it will not
drape over the counter or table top where it could be
pulled on by children or tripped over unintentionally.
(3) the appliance is of the grounded type, the cord set
or extension should be a grounding-type-wire cord
(applicable if grounding-type-3 cord is used).    
5. Descaling
A
For safe & efficient operation of your Aurora appliance it is
important to descale regularly.
Untreated scale deposits prevent the element conducting
heat efficiently and may affect its performance.
The appliance will display the descale warning symbol when
B
the appliance requires the descale process.
Ensure the water tank is empty. Remove the filter and place
into a plastic bag and filter before starting the descale
process.
C
Descale Procedure:
1. Fill water tank with 105fl oz./3L of white vinegar
(minimum 4% acidity).
2. Place a 3 liter jug under dispense nozzle.
3. Press and hold the descale warning symbol for 3 seconds.
D
4. The descale warning symbol will flash and the appliance
will run a descale process. Caution: Dispense solution
will be hot; around 194°F / 90°C. When the water tank is
empty, refill with 70fl oz./2L of cold water and press the
descale warning symbol again.
E
5. The appliance will run a cleaning cycle. Caution:
Dispense solution will be hot; around 194°F / 90°C.
6. The descale warning symbol will turn off once complete.
7. Re-insert the Aqua Optima filter after descale process is
complete.
3
F
8. The appliance is now ready to use.
SEC
Note:
• To abort the descale process, press the dispense button.
4
will light up red when

Publicidad