P1-13 = 11
P1-12 = 0
Input
L: 0 - 4 V DC
External Supply +24 V DC (100 mA)
Digital Input 1 (DI1)
Stop
Digital Input 2 (DI2)
Stop
Digital Input 3 (DI3)
AI1
Analog Input 1 (AI1): 0 - 10 V DC, < 20 mA, Frequency Setpoint value
[Digital Input 4 (DI4)] → P1-13
0 V
0 V
Digital Input 5 (DI5)
FF1, Fixed Frequency
[Analog Input 2 (AI2)]
(P2-01 = 5 Hz)
→ P1-13
Safe Tourqe Off
Stop
Safe Tourqe Off
Stop
10/14
H: 8 - 30 V DC
1
Enable,
2
Run Forward Rotation
Enable,
3
Run Reverse Rotation
FF1/FF2
4
5
6
7
8
9
FF2, Fixed Frequency
10
(P2-02 = 10 Hz)
11
STO+ (18 - 30 V DC)
12
STO- (0 V)
13
14
15
16
17
18
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
Emergency On Call Service: Local representative (www.eaton.eu/aftersales) or +49 (0) 180 5 223822 (de, en)
Output
+24 V DC, < 100 mA
+10 V DC, < 10 mA
0 V
Analog Output 1 (AO1): 0 - 10 V DC, < 20 mA, Output Frequency
[Digital Output 1 (DO1)] → P2-11, P2-12
0 V
Analog Output 2 (AO2): 0 - 10 V DC, < 20 mA, Output Current
[Digital Output 2 (DO2)] → P2-13, P2-14
Relay (K11 = COM)
Relay (K14 = NO), Healthy
Relay (K12 = NC), Error
Relay (K23 = COM)
Relay (K24 = NO), RUN
CANopen -
CANopen +
OV
→
OP-Bus -
OP-Bus +
+ 24 V
Modbus RTU -
Modbus RTU +