Descargar Imprimir esta página

Softing IT Networks CableMaster PoE Manual página 13

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

English
Power Class
Min Load
Max Load
1.6.4
Tone Generator
Press button (8) to open the menu for the tone generator.
Press the OK button (7) to switch the tone generator on and off.
The tone signal can be received with analog tone receivers such as the Softing CP15.
The Cursor Down key (6) can be used to switch between the selection of the tone mode and the wire pairs or wires.
The selected value can be changed with the Cursor UP key (2).
The tone mode can be set to HIGH, HIGH/LOW and LOW.
1.6.5
Length
The button (9) takes you to the menu for length determination.
Use the cursor buttons (2) and (6) to select between automatic length determination and length of individual wire
pairs.
Press the OK button (7) to determine the length.
With automatic length determination, the length of the shortest intact wire pair is always displayed.
The length can be determined against an open end or against a compatible remote.
1.6.6
Reset
1.7
Settings
Press the button (3) to open the settings menu.
Values in the settings can be adjusted using the cursor buttons (2) and (6) and the OK button (7)
The following options are available:
Units
Selection of the length unit between meters and feet
Capacitance
Capacitance of the cable in pf/m
This value is used to determine the length
Wiremap Setting
Selection between TIA568A and TIA568B color scheme
Crossover
Selection of whether crossed cables are permitted according to TIA.
Normal: No crossovers allowed
Crossover: Crossings 12-36 and 12-36 45-78 permitted
Energy Saving
Setting for energy saving
The AUTO OFF time Time for automatically switching off the device can be set in minutes
Beep
Sound On: short confirmation tone
Sound Off: No confirmation tone
Factory Reset
Resets the device to factory settings
CableMaster PoE Manual, Multilingual
PoE class, the maximum class provided by the switch is
always displayed
Voltage at lowest PoE load
Voltage at maximum PoE load
13
To reset the device,
insert a pin into the small
hole between the LED
and the RJ45 port and
press the reset button
within the housing.