Introduction
Disther was developed for testing high pressure pumps in the Common Rail
system, acting on the flow control valve (ZME, MPROP, IMV, SCV) and DRV
valves, in addition to controlling PCV valves of synchronized pumps and
measuring the cubic volume of the pump in tests predetermined by the
manufacturers of Common Rail pumps.
Disther does not perform any control over the test bench such as rotation, heating
of the test fluid, etc. The rotation adjustment must be carried out by the bench
operator.