NEW CONSTRUCTION
For Retrofit Installation - Skip to Page 6.
3. Attach damper/duct connector
to fan housing.
Push connector through opening from inside of housing.
Engage tabs and secure with screw from parts bag.
TABS
4. Mount housing to ceiling
structure.
Make sure bottom of housing will be flush with finished
ceiling.
For proper location using ½-inch ceiling material: Bend
out housing tabs to fit against bottom of structure.
Secure housing through mounting ears with
appropriate fasteners.
If mounting housing to I-joist, use wood blocking as
shown.
All manuals and user guides at all-guides.com
5. Connect 4-in. round duct.
6. Connect wiring.
Bend tab to expose desired access hole. Connect
power cable to housing with appropriate UL approved
connector. Connect wires per diagram on page 8. Re-
install wiring panel and secure with screw from parts
bag.
HOUSING
TABS