dispose of chemicals according to instructions in the Safety
Data Sheet (SDS).
Dispose of empty cylinders according to local, state and/or
federal regulations. Steel cylinders may be recyclable.
Check your local recycling center.
CLEANING
All CPDS Series 2 system fittings and valves should be
cleaned with Touch 'n Seal Poly-Clean.
WATER SEPARATOR
It is important to remove accumulated water from the air
compressor and the water separator. The air compressor (N)
and the water separator (R) both have manually operated
drains.
These should be checked daily and emptied according to
the manufacturer's manual provided with the CPDS Series 2.
ALTERNATIVE AIR PRESSURE SOURCES
The CPDS Series 2 operator may use dry nitrogen or an
external air compressor connected to the external air supply
quick coupler (Q) ¼ MNPT, ¼ body fitting on the back of the
CPDS Series 2 .
Warning! Input pressure from dry nitrogen or alternate
air compressors must not exceed 100 psi. The CPDS
Series 2 utilizes an air pressure booster. You must
use a pressure regulator with alternative air pressure
sources. Using alternative dry nitrogen or compressed
air in excess of 100 psi will raise the output pressure
above the maximum recommended level. Foam output
and quality will be affected and the system may be
damaged. The system warranty will be voided.
SYSTEM STORAGE
Store in a dry area between 60°-90°F (16°-27°C). DO NOT
store at temperatures above 120°F (49°C), near steam, open
flames, sparks, hot water pipes, chimneys, heat vents and
other heat sources. (Photo 8).
If the CPDS system remains inactive for a period of time, it
should be pressurized every week and chemicals dispensed
through the hoses until chemicals flow forcefully. This will
prevent crystallization of the chemical and clear "old"
product from the hoses.
After initial use, always store chemical hoses filled with
chemicals. Do not drain hoses.
Follow instructions in "SYSTEM SHUT DOWN PROCEDURE".
Unopened chemical tanks have a shelf life of approximately
one year from date of manufacture.
CAUTION
Building Codes
In many areas, building codes may restrict the use of cellular
plastics or polyurethane foam as exposed, finished material
applications. Under certain application codes, the use of
these materials may be prohibited. The foam produced by
this product is organic and may constitute a fire hazard if
improperly applied. Consult local building codes.
Surface Temperatures
Polyurethane foam should not be used in direct contact
with chimneys, heat vents, steam pipes, or other surface
areas that exceed 240°F (116°C). The cured foam should
not be left exposed or inadequately protected when used as
an interior or exterior finishing material. In all applications,
it is strongly recommended that the foam be protected by
approved facings and coatings.
Open Flame
Do not smoke near or operate the system in close proximity
to an open flame. Welding on or near cured polyurethane
foam requires special precautions.
Excessive Foam
To avoid spontaneous foam combustion and maximize
yields, carefully follow application instructions in the "FOAM
APPLICATOR OPERATION & TROUBLESHOOTING" section.
Weight (empty)
Height
Depth
Width
Foam Delivery Rate @ 160 psi
Foam Delivery Rate @ 200 psi
Maximum Hose Length
Power Source
Alternate Power Sources
Limited Warranty*
Foam Types
SAFETY PRECAUTIONS
"Safe Use, Storage & Handling" and "2-Component
Polyurethane Foam Instructions For Use," are included in all
Touch 'n Seal foam kits for the CPDS.
CAUTION. KEEP OUT OF REACH OF CHILDREN.
LIMITED WARRANTY: If product fails to perform when used
as directed, within one year from the date of purchase, call
888-DAP-TIPS, with your sales receipt and product container
available, for replacement product or sales price refund.
DAP will not be responsible for incidental or consequential
damages. See product label or Safety Data Sheet (SDS)
for safety information. You can request an SDS by calling
Photo 8
888-DAP-TIPS or by visiting our website at dap.com.
QUESTIONS?/ ¿ PREGUNTAS?: Call/llame al 888-DAP-TIPS or
visit/o visite dap.com & click on/y pulse en "Ask the Expert."
CPDS
SERIES 2 PROPERTIES
™
155 lbs (70 kg) approx.
49 in (125 cm)
33 in (84 cm)
24.5 in (62 cm)
4.0 lbs (1.8 kg) / minute
5.5 lbs (2.5 kg) / minute
100 ft (30 m)
120V, 15 amp
Pressurized Nitrogen, Dry Compressed Air
CP 750 FR, 2 Component, Fire Retardant (Closed Cell)
CP 1200 FR, 2 Component, Fire Retardant (Open Cell)
6 Months