Do not use a flame to check for leaks
from gas connections.
Checking for leaks with a flame
may result in a fire or explosion.
Disconnect this range and its individual shutoff
valve from the gas supply piping system during any
pressure testing of that system at test pressures greater
than 14" of water column pressure (approx. Y2" psig).
Isolate the range from the gas supply piping system
by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test
pressures equal to or less than 14" of water column
(approx. Y2" psig).
Back of
Range
Flexible
Connector
1/2"
Close Nipple
Recommended Shut-Off
tion
Flexible Connector Hookup
Figure 5
Union
Back of
Range
1
7/16"
3/_,,
_Wall
End of
Pressure
Regulator
iil
Counte_
:
Top
2 5//8"
TOP VIEW
FRONTVIEW
Solid Pipe Hookup Detail
Figure 7
5. LP/Propane
Gas Conversion
A. Pressure
Regulator
Conversion
NAT.
Figure 8
Cap Screw
Do Not Remove the Pressure Regulator
Remove cap-screw and snap out the nylon gas
indicator by pushing it sideways. Turn the nylon gas
indicator for type gas (Natural or LP) and snap it back
in the cap-screw.
Put cap-screw back on gas
regulator.
Y2" Nipple
IIII
IIII
I,-- 6 3/8" -_
Solid Pipe Hookup
Figure 6
4