* After pressing the button on the first transmitter the receiver will
wait 5 secs to memorise another transmitter.
In this way all the transmitters being associated with one channel
can be recorded in sequence. After the 5 secs the receivers exits
the programming mode. When using this method of recording in
sequence it is best to temporarily remove the antenna thereby
reducing the receiver's range and limiting disturbance.
N.B.: Once a programming mode has been entered, other modes
cannot be accessed.
When programming several functions complete one programming
sequence, indicated by the LED going out, and restart with a new
programming mode.
Mode
LED
Function
1
1
rapid blink
Press the button P for at least 2 secs
2
2
rapid blinks
Press the button P for at least 2 secs
3
3
rapid blinks
Press the button P for at least 2 secs
4
Off
Operations
If the P button is not pressed within 5 secs the channel is reset to the default
Set pulse mode
pulse mode (1 sec switching).
If the P button is not pressed within 5 secs the LED will start blinking at a rate
Select switching time
of 1 blink/sec until the button P is pressed.
The number of blinks counted before pressing the P button selects the
switching time, as shown in table 3.
Set
If the P button is not pressed within 5 secs the channel is set to the bistable
Bistable mode
mode: the relay changes status on each pulse.
No function
Normal status.
This function is only necessary when one of the two channels
has to be set to be timed (from 1 sec to 10 min) or with bistable
operation. The pulse operating mode is set by default (1 sec
switching).
To set the times enter mode 4 (for channel 1) or mode 5 (for
channel 2) and wait until the end of the 5 rapid blinks.
The Times submenu is described in table 2 below.
TABLE 2