Lámparas de rayos ultravioleta de alta intensidad uv-a

Publicidad

Idiomas disponibles

Idiomas disponibles

NOTE: The BP-12A battery pack includes a 12-volt battery, 120-volt charger and nylon carrying
case. (The BP-12A/F has a 230V/50Hz charger and the BP-12A/J has a 100V/50-60Hz charger.)
OPERATOR SERVICING
The following instructions are intended for limited servicing of the lamp. Do not perform any
servicing that is not covered in these instructions. Return the lamp to the factory for
maintenance not covered in this section.
HOUSING AND FILTER MAINTENANCE
CAUTION: Always shut off the switch on the ballast and unplug the ballast from the
power outlet before performing any maintenance or servicing. Allow the lamp to cool
before handling.
Clean the lamp and ballast housings with water and a mild detergent and wipe dry. Periodically
clean the filter with a glass cleaner and a soft cloth.
FILTER REPLACEMENT
The lamp is shipped with a 2F958 filter lens. This may be used with either the BLE-35RA
spot bulb or the BLE-35RAF flood bulb. The 2F350 filter lens may be ordered with a
BLE-35RA spot bulb (only) to produce a more diffused spot beam that is not as wide as
the flood beam.
1. Peel the filter holder from around the circumference of the lamp housing.
2. Press the existing filter out of the filter holder.
3. Press the new filter gently but firmly into the rubber filter holder.
4. To reattach the filter holder, press it with the heel of your hand around the
circumference of the lamp housing. Be sure the groove in the filter holder seats
over the rim of the housing.
BULB REPLACEMENT
Use only a Spectroline UV bulb/reflector assembly. Using any other bulb may damage the
unit and will void the warranty. The lamp is shipped with a BLE-35RA spot bulb/reflector
assembly as standard. The lamp may be ordered with a BLE-35RAF flood bulb/reflector
assembly.
1. Remove the filter holder.
2. Remove the existing bulb/reflector by turning its rim counterclockwise.
3. Hold the new bulb/reflector by its protective cover while inserting it into the socket with a
clockwise quarter-turn bayonet action. Firm pressure is needed to overcome the spring in the
socket. Pop off the black fastener and remove the protective cover.
4. Reattach the filter holder.
UV INTENSITY VERIFICATION
To ensure that the lamp is operating at a UV intensity sufficient to meet military and aerospace
specifications, the intensity should be checked periodically. The Spectroline DM-365HA digital
radiometer or the DSE-100H digital readout unit are specially designed to measure long wave
UV irradiance in the spectral range from 320-400nm.
NOTE: To measure long wave UV, the DSE-100H must be used with the DIX-365A
interchangeable sensor. It can also measure visible light in the spectral range from
380-760nm by using the DIX-555A or DIX-555A/L interchangeable sensors.
ELECTRICAL SPECIFICATIONS
Maxima Model
Power Source
BP-12A
Power Source
ML-3500M
120V/60Hz/1.00A
12VDC
ML-3500M/F
230V/50Hz/0.75A
12VDC
3
ML-3500M/J
100V/50-60Hz/1.00A
12VDC

Publicidad