KemiDose | pH · ORP · Chlorine
4. TECHNICAL SPECIFICATIONS
Specifications
Dimensions (H–W–D)
Weight
Pump state
Probe calibration
Power supply
Consumption (W)
Device precision
Accuracy
Range
Flow rate pump (l/h)
Max. back-pressure
Relay contact (number 3)
Fuse
Frequency pump dosing
0000139024
KemiDose Double PH/ORP
0-14pH; -99 -1000mV; 0...+55°C
250 Vac 10A (resistive load)
205.1
H:196x W:205x D:171 mm
6 Kg
Pause – Supply
Automatic
220-240 VAC 50-60 Hz
20Watt
± 0.1 pH; ±10mV; ±1°C
±0,02pH, ±3mV; ±0,5°C
5 l/h
5 bar
500 mA (fast)
160 strokes/minutes
rev. 1.0
EN
KemiDose Double PH/ORP/Chorine
H:196x W:205x D:171 mm
6 Kg
Pause – Supply
Automatic
220-240 VAC 50-60 Hz
20Watt
± 0.1 pH; ±10mV; 0.1 ppm; ±1°C
±0,02pH, ±3mV; 0,05 ppm; ±0,5°C
0-14pH; -99 -1000mV; 0-5 ppm; 0...+55°C
5 l/h
5 bar
250 Vac 10A (resistive load)
500 mA (fast)
160 strokes/minutes
228.15
4