TN-S Network System, 2P
F1
L
L
N
N
PE
PE
F2
MET
TN-C Network System, 3P
F1
L1
L1
L2
L2
L3
L3
PEN
PEN
F2
MET
LEGEND:
If > 0.5 m add connection .
Mode of protection
1P
L-N, L-PEN, L-PE, N-PE (only TN-S)
3P
L-PEN
2P
L-PE, N-PE
4P
L-PE, N-PE
Not green / Nicht grün Autre que vert /
Green / Grün
Vert / Verde
No es verde / Non verde
1.42 [36]
.71
[18]
max. 2.7 [70]
max. 2.7 [70]
max. 2.7 [70]
inches
[mm]
TN-S Network System, 4P
F1
L1
L1
L2
L2
L3
L3
N
N
PE
PE
F2
MET
SPD Conductor min. cross section
z PE / PEN
SPD Earthing Conductor
ø min 16 mm
2
L / N
SPD Live Conductor
ø min 6 mm
2
Replace Plug
Sustituya la conexión
Stecker ersetzen
Remplacez la prise
Sostituire la cartuccia
2.84 [72]
2.13 [54]
max. 2.7 [70]
PH2 / SLOT ¼
4.5Nm
[35 lnf∙in]
SA0 1P, 2P, 3P, 4P A320R Series
Product name
U
/U
AC (50-60Hz) 240 V + 6%
o
n
U
AC 300 V
C
U
1500 V
p
I
(8/20)
20 kA
n
I
(8/20)
40 kA
max
I
(10/350)
12.5 kA
imp
I
/ Backup fuse (per IEC 61643-11)
50 kA / 160 A gG fuse
SCCR
I
≤ 0.7 mA
PE
Ta
-40 ºC to +85 ºC [-40 ºF to +185 ºF]
RH
5 %...95 %
Mounting
35mm DIN rail, EN 60715
Altitude (max)
4000 m [13123 ft]
Location / Number of ports
Indoor / 1
IP
20 (built-in)
ø min 1.5 mm
/ ø max 35 mm
2
(solid, stranded) 18 mm
ø min 1.5 mm
/ ø max 25 mm
2
(flexible) 18 mm
ø min 0.25 mm
/ ø max 1.5 mm
2
RC push in (solid)
10 mm
ON
OFF
OFF
Green / Grün
Vert / Verde
Unplugged / Nicht eingesteckt
Débranché / Desconectado
Scollegato
1P
2P, 3P, 4P
Green / Grün
Vert / Verde
Unplugged / Nicht eingesteckt
Débranché / Desconectado
Scollegato
ON
OFF
ON
A.C.
D.C.
RC contact(s) states / Fernmeldekontakt(e)-Status
SPD module(s) functional / installation is protected
250V / 1A
48V / 0.5A
SPD-Modul(e) funktional / Installation ist geschützt
125V / 1A
24V / 0.5A
SPD module(s) unplugged or non-functional /
installation is unprotected | SPD-Modul(e) nicht eingesteckt oder
12V / 0.5A
nicht funktional /Installation ist ungeschützt
Protection against short circuit
L
Isccr = 50kA
F1
F1 ≤ 160A gG
S1
F2
F2 not needed
Recommended conductor cross section
F1
≤ 40A
63A —80A
100A — 160A
F2
-
-
-
S2
S1
6mm
10mm
25mm
2
2
2
S2
16mm
2
16mm
2
25mm
2
[ø min 15 AWG / ø max 2 AWG]
2
[ø min 15 AWG / ø max 4 AWG]
2
[ø min 23 AWG / ø max 16 AWG]
2
Step 1: Unlock / Schritt 1: Entsperren /
ON
OFF
ON
Étape 1: Déverrouillage / Paso 1: Desbloquear /
Fase 1: Sbloccare
Not green / Nicht grün
Autre que vert / No es
verde / Non verde
Not green / Nicht grün
Green / Grün
Green / Grün
Autre que vert / No es
Vert / Verde
Vert / Verde
verde / Non verde
Step 2: Pull module out / Schritt 2: Modul herausziehen /
Étape 2: Extrayez le module / Paso 2: Sacar el módulo /
ON
OFF
OFF
Fase 2: Tirare fuori la cartuccia
11- 12
11-14
Closed
Open
Geschlossen
Offen
Open
Closed
Offen
Geschlossen
F1 > 160A gG
F2 ≤ 160A gG
> 160A
≤ 160A
25mm
/ 35mm
2
2
25mm
2
/ 35mm
2