Intelligent Memory
The battery charger has a memory function that remains the last charging mode after
the new start. (Repair mode without memory function)
Connecting to the Battery
Do not connect the AC power plug until all other connections are made. Identify the
correct polarity of the battery terminals on the battery.
1. Connect the positive (red) battery clamp to the positive (+) battery terminal.
2. Connect the negative (black) battery clamp to the negative (--) battery terminal.
3. Connect the battery charger into a suitable electrical outlet. Do not face the battery
when making this connection.
4. After the positive and negative clips are connected, the LCD screen will light up,
battery charger starts to auto-detect the temperature, voltage, current and remaining
capacity (Note: After the charging ended, the battery needs to be put for an hour and
the remaining capacity of the battery will be shown in the below picture).
5. After the AC plug is connected, the screen will display "
the desulfurization process and will automatically switch to charging mode within 5 minutes.
The screen will keep displaying battery voltage, current and working
temperature during charging.
6. If the screen is flashing "
clips should connect incorrectly or abnormally.
7. Select the suitable charging mode accordingly.
8. The screen will show FUL after the charging is ended, we suggest you to keep
charging for 2 hours until the screen displays OFF for better battery performance.
9. When disconnecting the battery charger, disconnect in the reverse sequence,
removing the negative first (or positive first for positive ground systems).
14.00
13.00
12.00
11.00
10.00
0
20
Remaining capacity %
" and display EI-I also keep beeping sounds, then the
40
60
80
EN - 4
100
" which means entered