For overhead use, always install a safety-rope that can hold at least 12 times the weight of the fixture. You
must only use safety-ropes with screw-on carabines. Pull the safety-rope through the attachment eyelet on
the rear panel of the device and over the trussing system or a safe fixation spot. Insert the end in the
carabine and tighten the safety screw.
Use the safety-rope exclusively as a closed ring. Never use by only securing at each end. The maximum
drop distance must never exceed 20 cm.
A safety rope which already hold the strain of a crash or which is defective must not be used again.
Adjust the desired inclination-angle via the mounting-bracket and tighten the fixation screws.
Before taking into operation for the first time, the installation has to be approved by an expert!
Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
OPERATION
Switch the device on via the power switch. Connect the remote control with the Remote Control-socket.
After a certain warm-up time, the device is ready to operate. Then the stand-by lamp of the remote control
lights up. By operating the smoke switch on the remote control the smoke emission starts. It may happen
that the stand-by lamp turns off and the smoke emission stops. In this case the device is heating up again
and will be ready to operate in approx. 1-2 min. This process guarantees an appropriate vaporization
temperature and the best smoke emission possible. The temperature is regulated by a high quality
thermostat.
CAUTION: The escape nozzle will heat up during operation. Therefore do not touch the nozzle until it
has cooled down completely.
CLEANING AND MAINTENANCE
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
Clean the escape nozzle frequently from smoke fluid residues. Clean out debris with vinegar and a pipe
cleaner, making sure that the hole is free of clogs.
DANGER TO LIFE!
International
L
N
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!