GENERGY 5.2KW DC48V Instrucciones De Uso página 76

Sistema solar todo en uno

Publicidad

Idiomas disponibles

Idiomas disponibles

(2) RS485 Battery pack parallel function:
1. Under parallel status, communication address 0001 is Master battery pack, rest
communication position are slave battery. And slave battery could communication
with master battery pack through RS458 port. Master battery pack will collect all
slave battery data.
2. When parallel status, only master battery pack communicate with PC upper
computer as remote monitoring, uploading data, displaying status and any other
info of all battery packs.
Processing several pack parallel communication, need to set the single pack DIP
firstly, and take BCD format as follows.
RS232 (connecting with upper computer to let manufacturer or professional engineer to
process adjusting service):
(1) RS232 Communication port definition:
Diagram RS485 Parallel cables connection
Multiple sets of batteries in parallel use the DIP
74