E4BP-UP
4820391 4-channel transmitter
E4BPX-UP
4820392 4-channel transmitter with antenna
All UP receivers are compatible with UP transmitters
(remote controls, wall-mounted remote controls, flush-mounted
transmitters).
Installation
The E4BP(X)-UP can be wired behind pushbuttons (or switches)
of any civil series. If the receivers are MTR500, MTR1300,
MTR3600, MVR500, switches can be used instead of buttons.
It is not essential to wire the 4 channels: it is also possible to
use only one button connected to one channel. Insulate unused
cables.
When the receiver is switched on: :
- If the receiver is not part of a ZigBee network,
its LED is lit steadily
- If the receiver is already part of a ZigBee network,
its LED is off
.
To disconnect from a ZigBee network, press and hold the
button on the receiver for at least 10 sec.
Functions and configurations
WARNING!
To configure a transmitter, you must first access the Configuration Menu.
Wiring case with button
Wiring case with switch
Case of non-wired E4BP(X)-UP module
While the LED is flashing, push for the number of times (N) corresponding to the desired configuration
on the key to be programmed.
MTV300 dimmer case:
one push on the transmitter button switches the light on/off;
Push and hold the button to make the change.
7/21
Flush-mounted 4-channel ZigBee radio
transmitter
(contains: insulating nut, antenna holder and external antenna)
.
Disconnect the power
supply to the system
before commissioning
Do not connect this
230V
product to 230V mains
voltage.
Push the button connected to the transmitter briefly 10 times.
►The transmitter LED will start flashing quickly
Briefly push the switch connected to the transmitter 10 times.
►The transmitter LED will start flashing fast
Short-circuit all wires for a few seconds until the transmitter LED flashes.
Access the product page
for further information.
250m in free air space or inside a 100m² house
with perpendicular crossing of a main wall or
slab.