2 INTRODUCTION
2.1 TYPE PLATE OVERVIEW
1. Model designation
2. Serial number
3. Electrical supply information
4. Regeneration heater power
2.2 MODEL DESIGNATION
1. Principle type
2. Model name
3. Regeneration heater type - the type of heater the unit is
equipped with.*
R = Resistive (electric)
G = Gas
S = Steam
2.3 SERIAL NUMBER STRUCTURE
current structure.
1. Unit (e.g. RLZ-102)
2. Special unit (aa) - code to indicate a special manufactured unit
SP = Special
The absence of SP indicates a standard manufactured unit; e.g. RLZ-102SP is a special
manufactured unit, and RLZ-102 is a standard manufactured unit.
3. Serial number (
) - serial number of the manufactured unit
001, 002, 003, 004... n
DC-31 T10, T16 EN.05
RECUSORB DR-50R
Nr DR-50R.0000XXX
Electric heater P nom 4 kW
Seibu Giken DST AB
Avestagatan 33
16353 SPÅNGA, Sweden
HW = Hot water
WW = Warm water
D = Diesel
O = Oil
9
3 x 400V ~ 50Hz
P motors 0.23kW
P tot
I tot
RECUSORB RLZ-102R
Nr DR-50aa.bbbbbbb
4.3 kW
10 A
Seibu Giken DST
EN