Pottery Barn – Pottery Barn Teen – Pottery Barn Kids – Williams Sonoma Home – West Elm – Rejuvenation – Mark and Graham – GreenRow
21-Sep-2023
To Make the Wire Connections:
1. Gently pull existing wire down from the ceiling junction box and allow wires to hang. The HOT or LIVE wire is usually
black. The NEUTRAL wire is usually white. Check to see if there is a ground wire that is usually green or green with a
yellow stripe or exposed copper metal wire. If need, use a pair of wire strippers to remove about 1/2 inch of insulation
from each wire.
2. Fixture wires must be connected to the appropriate house wires - black fixture wire to black (power) house wire and
white fixture wire to white (neutral) house wire. If your fixture has lamp cord wire, connect the smooth fixture wire to the
black (power) house wire and connect the fixture wire with the ridges along the outer edge to the white (neutral) house
wire.
3. Carefully inspect the fixture wires. The NEUTRAL FIXTURE WIRE is White. The HOT FIXTURE WIRE is Black, and
the GROUND WIRE is Bare. If you have any doubt and cannot identify the power-supply wires with confidence, then
we recommend that you ask an electrician and that you not continue with the installation.
4. With the help of another person to hold the weight of the fixture, attach the fixture wires to the junction box wires as
shown in the illustrations.
NOTE: IT IS IMPERATIVE THAT THE JUNCTION BOX IN YOUR HOME BE PROPERLY GROUNDED!
DO NOT REVERSE THE HOT AND NEUTRAL CONNECTIONS OR SAFETY WILL BE COMPROMISED.
5. Check the wiring connections and if all looks good, gently tuck the wire connections neatly into the ceiling junction box.
Williams-Sonoma Inc.
Connect the GROUND FIXTURE WIRE to the GROUND J-BOX WIRE
(usually green insulation of bare wire) using the Plastic Wire Nut Connector
(A) and wrap the connection with electrical tape. Be sure that no wire
strands are exposed.
If the junction box DOES NOT have a GROUND WIRE, wrap the fixture's bare
ground wire around the Green Ground Screw (B) and insert the screw into the
Mounting Plate (C), marked as "GND", and tighten screw to secure the wire.
Connect the NEUTRAL FIXTURE WIRE to the NEUTRAL J-BOX WIRE
(usually white insulation) first and then connect the HOT FIXTURE WIRE to
the HOT J-BOX WIRE (usually black insulation) using the Plastic Wire Nut
Connectors (A). Wrap these connections with electrical tape. Be sure that
no wire strands are exposed.
Assembly Instructions
Instructions d'assemblage
Instrucciones de Ensamblaje
12/14
US/CA-A