Detector de fugas por humo

Publicidad

Idiomas disponibles

Idiomas disponibles

REF.54524
3. Clean the opening and avoid sharp objects
before put the adaptor in.
4.Put the intake adaptor Cone (or the universal
Intake Adaptor) into the opening. As bellows:
5. Connect power to 12V vehicle battery. For
best performance, the vehicle battery shall
be fully charged. Do NOT use a DC12V switch
power supply.
6. Now the unit shall generate pressurized air
flow.
7. Introduce the smoke nozzle into the system
via the Intake Adaptor Cone (or the Universal
Intake Adaptor).
8. Switch on the smoke mode, the unit will start
generating smoke.
9. Pull off the smoke nozzle, and plug it back
again when there's obvious smoke coming out
of the smoke nozzle.
10. The system will be ready for leak check in
2 minutes. Use a bright light torch or working
lamp to assist.
11. After leak test, collect the Power Cords and
Smoke Tube, clean the Intake Adaptor Cone
(or the Universal Intake Adaptor) before sto-
rage.
MAINTENANCE
PARTS LIST (EXPLODEDE VIEW)
1. Handle
2. Pressure gauge
3. Indicator for power
4. Switch for smoke
5. Indicator for Smoke
6. Port of filling oil
7. Oil level
8. Powe inlets: RED to +
9. Power inlets: Black to -
10. Smoke outlet