Installation
WARNING:
Electrocution hazard. To avoid personal injury or
death from electrocution, remove all sources of power and
allow stored energy to discharge before installing or removing
equipment.
Caution:
For general guidelines on system planning, design,
installation, commissioning, use and maintenance, refer to the
EN 54-14 standard and local regulations.
Installing the mounting base
Surface mount the base using 2 x M4 screws.
Three cable knockouts are provided for cable entry (see
Figure 2). Remove the knockouts before installation.
The mounting base also includes an optional address tag for
device identification (see Figure 1).
To use the address tag:
1.
Remove the address tag from the center of the mounting
base (by breaking it off).
2.
Add the device address to the address tag.
3.
Push the address tag into one of the slots in the mounting
base (see Figure 2).
Wiring
Wire the mounting base as shown in Figure 1. Connections for
each terminal are shown below.
Terminal
Description
1
Remote indicator negative (–)
2
Negative line (A–)
3
Negative line (B–)
4
Positive line (B+)
5
Positive line (A+)
6
Remote indicator positive (+)
7
Earth
Specifications
Number of terminals
Remote indicator terminals
Application
Polarity sensitive
Operating environment
Operating temperature
Storage temperature
Relative humidity
Colour
KE-DB3010W
KE-DB3010B
Material
Weight
Dimensions
2 / 14
7
Yes
Indoor use
Yes
−10 to +65°C
−30 to +75°C
10 to 93% (noncondensing)
White (similar to RAL 9016)
Black (similar to RAL 9011)
Polycarbonate resin PC-6620
55 g
Ø 100 × 17 mm
Regulatory information
Conformity
Manufacturer
Contact information and product
documentation
For contact information or to download the latest product
documentation, visit firesecurityproducts.com.
Product warnings and disclaimers
THESE PRODUCTS ARE INTENDED FOR SALE TO AND
INSTALLATION BY QUALIFIED PROFESSIONALS.
CARRIER FIRE & SECURITY B.V. CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY "AUTHORIZED DEALER" OR
"AUTHORIZED RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL FIRE AND
SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers
and product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code:
DE: Installationsanweisungen
Abbildungen
Abbildung 1: Verkabelung der Klasse A
(1) Adressetikett
Abbildung 2: Einschub für Adressetiketten und
Kabelausstanzungen
(1) Adressetikett
(2) Einschübe für Adressetiketten
(3) Kabelausstanzungen
Beschreibung
Diese Installationsanweisungen enthalten Informationen zu
den Standardmontagesockeln der Serie 3000, die in der
folgenden Tabelle aufgeführt sind.
Modell
Beschreibung
KE-DB3010W
Standardmontagesockel für intelligente
adressierbare Melder der Serie 3000 (weiß)
Standardmontagesockel für intelligente
KE-DB3010B
adressierbare Melder der Serie 3000 (schwarz)
P/N 3102987-ML • REV 002 • ISS 27FEB24
Dongguan Fyrnetics Co., Ltd.,
No.1 Rongwen Road, Changan,
Dongguan 523842, Guangdong, China.
Authorized EU manufacturing
representative:
Carrier Fire & Security B.V.,
Kelvinstraat 7, 6003 DH Weert,
Netherlands.