UNDERVOLTAGE
When the voltage is lower than 7 V for 5 seconds, the BRS-250 will switch off. This is to ensure that the relay
will still switch off when an (extremely) low voltage is detected. If the voltage is subsequently higher than
7.5 V for 5 seconds, the BRS-250 will be switched on again.
SWITCH
The button on the BRS-250 is meant for testing the relay quickly and easily. The relay will close when the
button is pressed and open again when the button is released.
STATUS / ALARM
The alarm output is active when the relay is closed, and inactive when the relay is open.
TECHNICAL DATA
ELECTRICAL
Operating voltage range
Current consumption
Inrush current (100 ms)
Switch-off current (50 ms)
Switching current
DIMENSION
Weight
Dimensions (L*W*H)
Mounting holes
Terminal strip contacts
CABLE DIAMETER
Flange connectors (T1 & T2)
Connections faston 6.3 mm
6.5 V to 35 V
Active ±1.4 mA
Passive ±0.7 mA
12 V mode 2.6 A
24 V mode 5.0 A
12 V mode 2.6 A
24 V mode 5.0 A
Continuous 250 A @ 25 °C
Peak 1,500 A @ 25 °C
370 g
120*82*57 mm
Ø 5 mm
L*W*H: 18*19*2 mm
Ø: 8 mm
minimum Ø: 50 mm
2
minimum Ø: 1.5 mm
2