INSTALLATION
Electrical Connection
Before installing electrical connection. inspect the heater nameplate and determine if you have a 120 VAG or a 240
VAG unit. Install a separate 120 VAG 15 AMP or 240 VAG 15 AMP dedicated circuit with GFGI protection. Using a
#8 solid copper wire, bond the heater as per approved local bonding codes. A bonding lug is provided on the heater.
At initial start-up with power ON, push the GFGI test button. The reset button should pop out. Push this button in
to reset. If the interrupter fails to operate in this manner, there is a ground current flowing or a device malfunction,
indicating the possibility of electrical shock. Turn OFF power and do not use the bath until the source of the
problem has been identified and corrected.
ELECTRICAL
CONNECTION
SEPERATE GFCI
PROTECTED CIRCUITS
~
HEATER
To Install Heater
A coil of
#8
solid copper bonding wire is supplied with
the heater. Use this wire to bond the heater to the house
electrical panel or approved local bond. A bonding lug is
provided on the heater.
~
BONDING LUG
'L
-'''- (jj
..
~
rapidfiheal
n
,--,
m
III
1. Locate the plumbing line from the inlet (suction) fitting to the pump. The heater blank
wilitie
in this line.
2. Unscrew both union nuts at the ends of the heater blank and remove blank. Leave the gaskets in place on the
plumbing connections.
3. Insert the heater in the open space in plumbing with the reset button and light facing away from the bath. Make
sure the gaskets remain in place. Tighten the union nuts hand tight. Do not plug the heater in at this time.
4. After installing the heater, added support for the inlet line must be provided. Use a cable tie through the anchor.
The inlet line should slope evenly from the pump to the inlet fitting for proper pump drainage.
5. After installing heater and support, fill the bath and check for leaks with pump/motor OFF. Then check for leaks
with the pump ON.
6. Turn the pump OFF and plug the heater in the separate GFCI protected outlet. Tum the pump back ON and check
that the heater light is ON indicating that the heater is operating. If light is not lit, check the electrical connections
to outlet.
IN LINE INSTALLATION
SIDE VIEW OF BATH
/
J
ANCHOR
~
\,
CABLE
R
TIE
/
\
--~i
'"
!
i
H
'
I
+ -
,
~~
-
\
HEATER BLANK
TO SUCTION FITTING
Jacuzzi Whirlpool Bath'
BE97000C
9/05
PUMP
2
PLUMBING ASSEMBLY
FROM
SUCTION
FITTING
GASKETS
TO PUMP

Publicidad