OPERATIONS INSTRUCTION
Preparation
before use
Detail
operation
during use
Install the hook onto the hook port (A) and hang under the
hood.
Open the filling cap and drain 10ml of test liquid into the filling
port (B).
NOTE
If the test oil is overfilled, turn the device upside down to drain
out part of the oil.
Start using the SDT106 after the first two steps.
Fit the smoke hose to the smoke outlet (F) and the power cord
to the power socket (E).
Connect the power clip to the DC 12V car battery.
NOTE
The red clip is connected to the positive terminal (+) and the
black clip is connected to the negative terminal (-). For optimum
performance of the smoke leak detector, the car battery should
be fully charged in advance.
NOTE
This machine only allows to use DC 12V car battery as power
supply.
The built-in air pump starts to work to produce pressurized air
after power on.
Press the smoke control switch (D), the LED indicator (C) lights
up, and the detector starts to work and produces smoke.
NOTE
When the internal temperature reaches 75°C, the product will
start self-protection function and stop working automatically.
Press the smoke control switch (D) again to stop the smoke
output.
It is recommended to drain out the remaining test oil for next
5