Translation of the original instructions
OPERATING INSTRUCTIONS
TECHNICAL DATA
Light Source
Luminous Power
Operating time
Battery Specification
Charging Time
Charging Input
Degree of protection
Operating temperature
WARNING
• Do not open the device.
• Do not look directly into the light emitting lamp - Risk of eye injuries!
• Do not operate in direct sun light or extreme temperature conditions.
• Operating temperature, -10°C to +40°C.
• Keep away from children! Children should be supervised in order to ensure that they do not play with the device!
OPERATING & CHARGING PROCEDURE
• PRO INSPECTION LAMP - Operating mode :
- Press the button once, the top LED lights up (120 Lm).
- Press the button a 2nd time, the main LED lights up at medium power (150 Lm).
- Press the button a 3rd time, the main LED switches to full power (800 Lm).
- Press the button a 4th time, the LED on the back lights up at medium power (120 Lm).
- Press the button a 5th time, the LED on the back switches to full power (400 Lm).
- Finally, press the button a 6th time to turn the lamp off.
• When a mode is used for more than 5 seconds, pressing the button turns the lamp off. Press the button again to
switch the lamp back to the last used mode.
• Connect the lamp with the supplied USB charging cable to recharge it.
• The 3 green LEDs indicate the charge status. If they are all off, then the lamp is completely discharged.
• When charging, the flashing LED indicates how far the battery is recharged.
• The charge is complete when all green LEDs are solid.
• If the charging indicator does not light up, disconnect and then reconnect USB cable.
• Always use the USB cable recommended for this lamp.
• Using a non-recommended cable can cause a fire and destroy the lamp
• Charge the lamp for 4-5 hours before first use.
• Charge the lamp to 100% before storing it for a long time.
SAFETY INSTRUCTIONS
• Do not use the device if there is damage to the housing, plug or cable. Consult your local authorized specialist!
• Do not open the device! Repair work and replacing the rechargeable battery pack may only be carried out by electricians.
• Carry out cleaning tasks only when the mains plug is removed from the mains power!
• There is a risk of short-circuit. Repairs on the device may only be carried out by commissioned and trained persons.
Please contact your nearest authorized branch.
• Protect the battery against heat, e. g., against continuous intense sunlight, fire, water, and moisture. Danger of
explosion.
4
INSPECTION LAMP PRO 800L
Keep this instruction manual for future reference or for subsequent possessors.
High power COB LED
ca. 120 lumen - Top LED
ca. 150/800 lumen - Main LED
ca. 120/400 lumen - Back LED
ca. 8 h - Top LED
ca. 8/2,5 h - Main LED
(min/max)
ca. 9/4 h - Back LED
(min/max)
Li-Ion 3.7 V, 2600 mAh, 9.62 Wh
ca. 4 h
DC 5V 1A
IP 54 , IK 07
-10 °C to +40 °C
(min/max)
(min/max)
EN