Universal Receiver Instruction
RX UNICOM2 MULTI-FREQUENCY
TECHNICAL FEATURES
Alimentation
Current consumption
Relay number
Relay Configuration
Radio Module
Max. number of storable
codes
Box Dimensions
Operating Temperature
IMPORTANT WARNINGS
Dear customer, thank you for purchasing one of our products. Please read
and retain this instruction manual carefully as it provides important information
about the operation and safety of the device.
- The descriptions and outlines contained in this prospectus are not binding.
HR MATIC, keeping the main characteristics of the equipment unchanged,
reserves the right to update this brochure at any time and without
obligation for technical improvements or for any other commercial reason.
- The receiver must be used exclusively for the use for which it was designed.
Any other use will be considered inappropriate and therefore dangerous.
1 – REGISTRATION OF CONTROLS IN RECEIVER
Up to a maximum of 40 codes can be registered on the receiver.
NOTE: Each button on the remote control corresponds to a code. Example:
If you record all the channels of a 4-push knob, 4 are entered
codes on the receiver.
1..1 - STANDARD PROCEDURE:
- Press the P button on the receiver to select relay 1, the L1 LED starts flashing.
To switch to relay 2, press the P button again, the L2 LED starts flashing.
- After selecting the desired relay, press the button on the remote control you
want to register and hold it down until the L1 and L2 LEDs remain solid on, it
may take a few seconds before the receiver decodes the new code.
- Repeat for all the codes you want to enter into the receiver.
12-24 Vac/Vdc
20mA typica, max. 50mA
2
Bistable, Impulsive, Minute Timer and
Second Timer
433.92-868 MHz
40
53x76x24 mm
-20 °C / +70 °C
1.2 –COMPLEX PROCEDURE:
- Press the P button on the receiver to select relay 1, the L1 LED starts flashing.
To switch to relay 2, press the P button again, the L2 LED starts flashing.
- After selecting the desired relay, press the button on the remote control you
want to register and hold it until the LED on the relay (L1 or L2) remains solid
and then emits 2 slow flashes.
-Transmit the seed code via the hidden key or button combination. If you don't
know the procedure or don't have the ability to transmit the seed code,
continue pressing the button on the remote control you're trying to register,
it will be stored as a fixed code.
CHECK:
When the code is memorized correctly, both LEDs remain
Shortly thereafter, the L2 LED will flash twice.
2 – CANCEL CONTROLS
This function allows you to individually remove the controls present
inside the receiver:
- Press the P button on the receiver, the L1 LED starts flashing, then press the S
button.
- The L1 and L2 LEDs light up steadily.
- Press and hold the button on the remote control you want to delete
until the L1 and L2 LEDs turn off. The remote control has been removed
Correct.
- Repeat the operation for all the codes you want to delete.
3 – RELAY CONFIGURATION
The relays can be configured in four different ways:
• Bistable: the relay status is maintained until another press of the knob
associate.
When the remote control is pressed, the relay contact closes, the next
Pulse opens. WARNING: the absence of power returns the exit to its resting
state, i.e., open contact.
• Impulsive (factory): the relay contact remains closed while
The pressure on the associated control lasts, once released it opens.
ATTENTION: Any disturbance may open the contact even if the
Button on the controller is still pressed.
• Seconds timer: this way it is possible to set a time
within seconds after which the relay contact is opened. The Timer
It comes factory set in 30 seconds. PLEASE NOTE: the timer is
It recharges every time an associated transmitter is pressed.
• Minute timer: this way it is possible to set a time
within minutes after which the relay contact is opened. The Timer
It comes factory set up in 30 minutes. PLEASE NOTE: the timer is
It recharges every time an associated transmitter is pressed.
3.1 - PROCEDURE FOR SETTING UP RELAYS 1 & 2:
- Press and hold the S button on the receiver for about
5 seconds.
- The L1 LED corresponding to relay 1 begins to flash, to pass to the
Relay 2 press the S key, then the L2 LED starts flashing.
- The LED (L1 or L2) of the selected relay flashes according to the
configured mode:
☼
1 FLASH
☼ ☼
2 FLASHES
☼ ☼ ☼
3 FLASHES
☼ ☼ ☼ ☼
4 FLASHES
- Press the P button to change the desired operating mode. Each time the P
button is pressed again, the setting switches to the next mode cyclically.
- Exit the settings by repeatedly pressing the S button until the
LEDs turn off.
www.hrmatic.es
info@hrmatic.es
BISTABLE
IMPULSIVE
SECONDS TIMER
MINUTE TIMER